Question
What does operation resistance mean?
Answer
This is the resistance between electrodes that is required for the
61F Floatless Level Controllers and
K7L Liquid Leakage Sensors to operate. The
61F and K7L will definitely operate when the liquid or solid
inter-electrode resistance value is lower than the operation resistance
value.
Reference:
The higher this value is, the easier it is for the Level Controller to
operate even with low-conductivity liquids, thus raising the sensitivity
of the Level Controller.