Industrial Automation|

Malaysia

Sitemap

Contact

OMRON IA Global

 
Submit Enquiry

Member Area

Find out information related to K3FP.

Catalogs/Manuals

CAD Drawings

 


Related Contents

RoHS Compliant Status

Stock Availability

Select Country

 

Product Information

Product Index :: Industrial Components :: Other Components :: Interface Converters

K3FP Ultra-slim Signal Converter


K3FP Ultra-slim Signal Converter

 

Download Product Brochure

* Ordering information
* Specifications
* Configurations
* Dimensions, and etc

 

  can be found in our PDF brochure.
 

 

 

Complete Lineup of Ultra-slim, High- performance Converters for Every Application

  • Ultra-slim 6.2-mm size.
    Close mounting makes devices more compact.

  • Easily wired and flexible with 8 terminal blocks.

  • Multi-range I/O provides flexibility for the desired signal format.

  • High-precision analog conversion with minimum current consumption.

  • Reduced wiring through power supply connection with DIN rail bus connector (optional).

Product Lineup

 

K3FP-YV-I-I/K3FP-YV-U-U 3-Way Signal Isolator

  • Isolates between input, output, and power supply. 1,500 V AC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-VS-UI-UI 3-Way Signal Isolator with 36 Input and Output Combinations

  • Input and output ranges can be easily changed using an external DIP switch.

  • Isolates between input, output, and power supply. 1,500 V AC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-VS-UI-2I Dual Output 3-Way Signal Isolator

  • Outputs two isolated signals.

  • Isolated between input, output 1, output 2, and between power supply. 1,500 V AC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-SN1-I-I/K3FP-SN2-I-I Loop-powered Isolator

  • Draws the power required to drive the amplifier from the input current signal.

  • Isolated between input and output. 1,500 V AC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-TS-UI Thermocouple Transducer

  • Converts measured values for type J and K thermocouple sensors into analog signals.

  • Measurement range can be set between −150 and 1,350°C.

  • Isolates between input, output, and power supply. 1,500 VAC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-RS-UI RTD Transducer

  • Converts measured values from PT100 platinum resistance thermometers into analog signals.

  • A 2-conductor, 3-conductor, or 4-conductor PT100 platinum resistance thermometer can be connected to the input terminal.

  • Measurement range can be set between −150 and 850°C.

  • Isolates between input, output, and power supply. 1,500 VAC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-DY-I-I Repeater Power Supply

  • Isolates between input, output, and power supply. 1,500 VAC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

K3FP-SL-UI Limit Value Switch

  • Accurate setting of comparative judgment values using the Unit's potentiometer.

  • Isolates between input, output, and power supply. 1,500 VAC dielectric strength.

  • Close mounting.

  • CE Marking compliant.

  • UL certified.

 

Application Examples

 

Install in Limited Space

K3FP Series 

 

This ultra-slim 6.2-mm Signal Converter can be installed in limited space, such as where expansion is required, and help to reduce the overall size of devices.

Install in Limited Space

 

 

Isolators That Do Not Require Power Supply

K3FP-SN1-I-I  One-channel Passive Loop-powered Isolator 

K3FP-SN2-I-I  Two-channel Passive Loop-powered Isolator 

 

The input signal provides power for the Isolator, so power supply capacity does not need to be considered when expanding Units: No power line wiring is required.

 

Isolators That Do Not Require Power Supply

 

 

 

Reduce Spare Parts

K3FP-VS-UI-UI 3-Way Signal Isolator 

 

Input and output ranges are set using a DIP switch on the side of the Unit.

Reduce Spare Parts

 

 

 

Three- and four-conductor RTD Transducers

K3FP-RS-UI RTD Transducer 

 

Select the number of conductors for the input platinum resistance thermometer using the DIP switch on the side of the Unit. Set any input range from −150°C to 850°C.

Three- and four-conductor RTD Transducers

 

 

 

Isolated Duplicate Signal Output

K3FP-VS-UI-2I Dual Output 3-Way Signal Isolator 

 

Isolated Duplicate Signal Output

 

 

 

Limit Value Switches

K3FP-SL-UI Limit Value Switch 

 

Limit Value Switches

 

Note:
Consider the following products for judging non-DC signal inputs.
For AC current single-phase signal inputs: K8AB-AS

For AC voltage single-phase signal inputs: K8AB-VS/K8AB-VW
For AC voltage three-phase signal inputs: K8AB-PW
For thermocouple and platinum resistance thermometer sensor inputs: K8AB-TH

K8AB-TH Temperature Monitoring Relay

 

top

See Related Products:


K8AB Series Measuring and Monitoring Relays
 

Measuring and Monitoring Relays

 

 

K8AB Series

8 slim models featuring a variety of innovative new functions. 2 SPDT outputs available in models DIN sized at 22.5 mm.

K8AB-TH Temperature Monitoring Relay
 

Temperature Monitoring Relay

 

 

K8AB-TH

Compact and Slim Relay ideal for temperature alarms and monitoring.

61F-D21T-V1 Conductive Level Controller
 

Conductive Level Controller

 

 

61F-D21T-V1

Ideal for level control for industrial facilities and equipment.