Advanced Features in 3 Aspects
Wide Area
Ionizes areas wider than the Ionizer
itself.
Short Distance
Achieves the highest level of
short-distance ionization in its class.
Long Distance
Steady ionizing performance, even over
long distances.

Three Technologies Supporting
Effective and Efficient Ionization
Technology 1: Ion Sensing and
Variable-AC System (Industry First!)
An ion sensor installed on the bottom of
the Ionizer detects the charge and ion balance. The applied voltage is
flexibly controlled according to the ion
balance conditions to raise ionization efficiency.

Technology 2: Micro Power Spraying (MPS)
Structure
High-speed airflow is achieved by
minimizing the air nozzle diameter. An optimal cone shape is also
employed for the inside of the nozzle to further improve ion
dispersion. By using a special ring guard shape to pull passive
(external) air into the active air stream, the total airflow is
dramatically increased.

Technology 3: Optimized Discharge
Electrode Pitch Optimized Discharge Electrode Pitch
Setting the discharge electrodes at a
pitch that is 80 mm longer than in our previous models achieves an
optimal layout that unifies ionizing performance and reduces ion
recombination. This model ionizes over long distances with or without
the use of an Air Purge Ionizer.

Uniform Ionization
Linked Ionizers cover a wide area
without causing uneven ionization.
Linking up to 7 Units *
Long Ionizers are required to meet the
needs of increasingly large liquid crystal glass panels. Ionizers as
long as two meters are not only difficult to transport and install,
but also pose difficulties in achieving uniform ionization. The highly
thorough ZJ-BAS Ionizer solves this problem by connecting Ionizers
together.
* For information on requirements for
linking Ionizers, contact your OMRON sales representative.
Two Forms of Uniform Ionization
Achieved by Linking Function
Uniform Airflow
The air supply ports on previous models
were only on both ends, so the airflow was weak in the center of long
Ionizers. By connecting ZJ-BAS Ionizers together, air is supplied from
the center part as well, thus achieving a uniform airflow and
eliminating uneven ion discharge at medium and long distances.

Uniform Ion Balance
For example, when both sides of a
workpiece are charged, a long Ionizer will adjust the amount of ions
according to the entire Ionizer length, so an area that is not charged
may take on a reverse charge. By using linked ZJ-BAS Ionizers, each
Ionizer senses the charge condition. Because only the Ionizers on both
ends then control their ion amounts in response to the charges,
reverse charging does not occur.

Technologies that Support Uniform
Ionization
Technology 1: Supplying air with no
pressure loss
By arranging discharge electrodes on
both ends, the Ionizer can handle an area wider than the length of the
Ionizer itself. This eliminates dead zones even when linking Ionizers,
and achieves uniform ionization.

Technology 2: Ion Sensing and
variable-AC system prevents ion recombination
Because the ZJ-BAS Ionizer uses a method
in which the linked Ionizers operate using the same power supply, the
positive and negative ion generation timing between the Ionizers is
synchronized. Also, the sensing and variable-AC system control the
amount of ions while synchronizing the Ionizers. This reduces ion
recombination between the linked Ionizers, and achieves uniform
ionization.
Ion Sensing and Variable-AC System
(refer to left graph below)
The amount of ions is adjusted even when a charge is detected, so
synchronization with matching polarity is maintained.
AC System (Refer to right graph below)
If the synchronization of the timing is lost, the polarity is
reversed.

Improving Ease of Use
The Digital Ion Display Supports
Safe, Reliable settings (Industry First)
From either the Remote Control or the
Ionizer...
The Digital Ion Display guides you when
making settings. Settings that are important for ionization
performance, such as the frequency and ion balance, can be made and
displayed safely and reliably from the ionizer itself, or by using the
Remote Control.
A Variety of Displays
Ion Balance Display
The charged state is displayed using
colors.

Set Value Display
The current set value is shown on the
right side of the display. The set value can be numerically confirmed,
so the setting can be quantified. This allows identical settings to be
made reliably and in a short time even across multiple Ionizers.

Operation Stop Mode Makes
Maintenance Easy
The Operation Stop Mode allows for safe
cleaning and replacement work. The digital display and LED lamps tell
you that the Ionizer is in Operation Stop Mode so you will not forget to
return to Operation Mode when you are finished doing maintenance. Both
regular operations and maintenance can be done safely and reliably.

Operations from external equipment, such
as stopping ionization and performing status management, can be done
easily by connecting the Ionizer to a PLC using an I/O cable.
Low Running Cost
M.P.S. Construction Prolongs the
Required Maintenance Period by 5 Times Compared to Our Previous Model.
Greatly Reduce Maintenance Requirements.
The M.P.S. nozzle emits clean air from
around the discharge electrode, thus decreasing the amount of foreign
matter adhesion, and dramatically extending the time before cleaning
is required.

Energy-saving is a Basic Concept for
OMRON Ionizers
Generally, bar-type Ionizers use
compressed air. Therefore, a large amount of compressed air is needed,
especially for long-distance or high-speed ionization. This increases
the load rate of the compressor, and consumes large amounts of
electricity. The ZJ-BAS uses an optimized discharge electrode pitch
and M.P.S. nozzle to improve ionization performance while using an
energy-saving structure (low-current consumption) that is
environmentally friendly.
The M.P.S. nozzle allows for efficient
airflow while reducing current consumption.

80-mm Discharge Electrode Pitch
Dramatically Reduces Replacement Cost
The 80-mm discharge electrode pitch and
variable-AC system reduce the number of discharge electrodes required
by 60%. In addition to reducing the cleaning time, the periodic
replacement of the electrodes has also been reduced, thereby
dramatically reducing the running cost of the Ionizer.

|
Effective length (mm) |
Number of Discharge Modules |
|
500 |
5 |
|
580 |
6 |
|
740 |
8 |
|
900 |
10 |
|
1300 |
15 |
|
1540 |
18 |
|