Page top

Industrial Automation

Industrial Automation

Discontinued On Jan. 2023

F3SG-R Series

Safety Light Curtain

F3SG-R Series

Offers Both Durability and Reliability

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

F3SG-RA Advanced type

Main unit

The [][][][] in the model names indicate the protective heights in millimeters.

F3SG-4RA[][][][]-14
F3SG-2RA[][][][]-14
F3SG-4RA[][][][]-30
F3SG-2RA[][][][]-30
Type of ESPE
(IEC 61496-1)
Type 4 F3SG-4RA[][][][]-14/-30
Type 2 F3SG-2RA[][][][]-14/-30
Perfor-
mance
Object Resolution
(Detection Capability)
Opaque objects
14-mm dia. 30-mm dia.
Beam Gap 10 mm 20 mm
Number of Beams 15 to 207 8 to 124
Lens Size 5.2 × 3.4 (W × H) mm 7-mm dia.
Protective Height 160 to 2080 mm (6.3 to 81.9 inch) 190 to 2510 mm (7.3 to 98.7 inch)
Operating
Range
Long 0.3 to 10.0 m (1 to 32 ft.) 0.3 to 20.0 m (1 to 65 ft.)
Short 0.3 to 3.0 m (1 to 10 ft.) 0.3 to 7.0 m (1 to 23 ft.)
Response
Time
ON to OFF Normal mode: 8 to 18 ms max. *1
Slow mode: 16 to 36 ms max. *1 *2
OFF to ON 40 to 90 ms max. *1
*1. Response time when used in one segment system or in cascaded connection.
Refer to the one segment system. Refer to Safety Light Curtain
F3SG-R Series User's Manual (ManNo.: Z352) for cascaded connection.
*2. Selectable by Configuration Tool.
Effective
Aperture
Angle (EAA)
(IEC
61496-2)
Type 4 ±2.5° max., emitter and receiver at operating range of 3 m or greater
Type 2 ±5.0° max., emitter and receiver at operating range of 3 m or greater
Light Source Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time 2 s max.
Elec-
trical
Power Supply Voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption Refer to "List of Models/Response Time/Current Consumption/Weight".
Safety Outputs (OSSD) Two PNP or NPN transistor outputs (PNP or NPN is selectable by DIP
Switch.)
Load current of 300 mA max., Residual voltage of 2 V max. (except for
voltage drop due to cable extension), Capacitive load of 1 μF max.,
Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1 The load inductance is the maximum value when the safety output
frequently repeats ON and OFF. When you use the safety output at 4 Hz
or less, the usable load inductance becomes larger.
*2 These values must be taken into consideration when connecting
elements including a capacitive load such as a capacitor.
Auxiliary Output One PNP or NPN transistor output (PNP or NPN is selectable by DIP
Switch.)
Load current of 100 mA max., Residual voltage of 2 V max .
Output
Operation
Mode
Safety Output Light-ON (Safety output is enabled when the receiver receives an
emitting signal.)
Auxiliary Output Safety output
(Inverted signal output:Enable) (default) (Cofigurable by Configuration Tool)
Input
Voltage
RESET (EDM) PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 8.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 8.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 6.5 mA) *
MUTE A/B PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 5.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 5.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 3.0 mA) *
TEST 24 V Active
ON voltage: 9 V to Vs (short circuit current: approx. 2.5mA) *
OFF voltage: 0 to 3 V, or open (short circuit current: approx. 2.0 mA)
0 V Active
ON voltage: 0 to 3 V (short circuit current: approx. 2.0 mA)
OFF voltage: 9 V to Vs, or open (short circuit current: approx. 2.5 mA) *
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category
(IEC 60664-1)
II
Indicators Refer to "Indicator".
Protective Circuit Output short protection, Power supply reverse polarity protection
Insulation Resistance 20 MΩ or higher (500 VDC megger)
Dielectric Strength 1,000 VAC, 50/60 Hz (1 min)
Func-
tional
Mutual Interference
Prevention (Scan Code)
This function prevents mutual interference in up to two F3SG-RA
systems.
Cascade Connection Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Cable length between sensors: 10 m max.
(not including cascading cable (F39-JGR2W) and power cable)
Test Function Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-Related Functions Interlock
External device monitoring (EDM)
Pre-reset
Fixed blanking/Floating blanking
Reduced resolution
Muting/Override
Scan code selection
PNP/NPN selection
Response time adjustment
Environ-
mental
Ambient
Temperature
Operating -10 to 55°C (14 to 131°F) (non-icing)
Storage -25 to 70°C (-13 to 158°F)
Ambient
Humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient Illuminance Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection
(IEC 60529)
IP65 and IP67
Vibration Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm,
Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions
(no delay at resonant frequencies)
Shock Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms,
100 shocks for each in X, Y, and Z directions (600 shocks in total)
Pollution Degree (IEC 60664-1) Pollution Degree 3
Connec-
tions
Power cable Type of
Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated,
Cables prewired to the sensors
Number of Wires Emitter: 5, Receiver: 8
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending Radius
R5 mm
Cascading
cable
Type of
Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Number of Wires Emitter: 5, Receiver: 8
Cable Length 0.2 m
Cable Diameter 6 mm
Minimum
Bending Radius
R5 mm
Extension
cable
- Single-
Ended Cable
- Double-
Ended Cable
Type of
Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Number of Wires Emitter: 5, Receiver: 8
Cable Length Refer to Lineup.
Cable Diameter 6.6 mm
Minimum
Bending Radius
R36 mm
Extension of Power Cable 100 m max.
Material Material Housing: Aluminum alloy
Cap: PBT resin
Front window: Acrylic resin
Cable: Oil-resistant PVC resin
Standard Fixed Bracket (F39-LGF): Zinc alloy
FE plate: Stainless steel
Weight Refer to "List of Models/Response Time/Current Consumption/Weight".
Included Accessories Safety Precautions, Quick Installation Manual, Standard Fixed Bracket *,
Troubleshooting Guide Sticker, Warning Zone Label
* The quantity of Standard Fixed Brackets included varies depending on
the protective height.
[F3SG-[]RA[][][][]-14]
- Protective height of 0160 to 1200: 2 sets
- Protective height of 1280 to 2080: 3 sets
[F3SG-[]RA[][][][]-30]
- Protective height of 0190 to 1230: 2 sets
- Protective height of 1310 to 2270: 3 sets
- Protective height of 2350 to 2510: 4 sets
Con-
formity
Conforming standards Refer to "Legislation and Standards".
Type of ESPE (IEC 61496-1) Type 4
Performance
Level (PL)/
Safety
category
Type 4 PL e/Category 4 (EN ISO 13849-1:2015)
Type 2 PL c/Category 2 (EN ISO 13849-1:2015)
PFHD 1.1 × 10-8 (IEC 61508)
Proof test interval TM Every 20 years (IEC 61508)
SFF 99% (IEC 61508)
HFT 1 (IEC 61508)
Classification Type B (IEC 61508-2)

Bluetooth Communication Unit

Communication System Bluetooth Version 3.0
Communication Profile SPP (Serial Port Profile)
Transmission Distance Approx. 10 m max. (Output power: Class 2) *

* It depends on use environment conditions.

List of Models/Response Time/Current Consumption/Weight

F3SG-4RA[][][][]-14/F3SG-2RA[][][][]-14

Model Num-
ber
of
Beams
Pro-
tective
Height
[mm]
Response Time
[ms] *1
Current
Consumption
[mA]
Weight
[kg]
ON

OFF
*2
OFF
(Syn-
chro-
nized)
→ ON
OFF
(Not
syn-
chro-
nized)
→ ON
Emitter Re-
ceiver
Net
*3
Gross
*4
F3SG-4RA0160-14 F3SG-2RA0160-14 15 160 8 40 140 40 75 0.7 2.0
F3SG-4RA0240-14 F3SG-2RA0240-14 23 240 8 40 140 45 75 0.9 2.3
F3SG-4RA0320-14 F3SG-2RA0320-14 31 320 8 40 140 55 75 1.1 2.6
F3SG-4RA0400-14 F3SG-2RA0400-14 39 400 8 40 140 60 80 1.3 2.9
F3SG-4RA0480-14 F3SG-2RA0480-14 47 480 13 65 165 50 80 1.5 3.2
F3SG-4RA0560-14 F3SG-2RA0560-14 55 560 13 65 165 55 80 1.7 3.5
F3SG-4RA0640-14 F3SG-2RA0640-14 63 640 13 65 165 60 85 1.9 3.9
F3SG-4RA0720-14 F3SG-2RA0720-14 71 720 13 65 165 65 85 2.1 4.2
F3SG-4RA0800-14 F3SG-2RA0800-14 79 800 13 65 165 65 90 2.3 4.5
F3SG-4RA0880-14 F3SG-2RA0880-14 87 880 13 65 165 70 90 2.6 4.8
F3SG-4RA0960-14 F3SG-2RA0960-14 95 960 13 65 165 75 90 2.8 5.1
F3SG-4RA1040-14 F3SG-2RA1040-14 103 1040 13 65 165 80 95 3.0 5.4
F3SG-4RA1120-14 F3SG-2RA1120-14 111 1120 13 65 165 85 95 3.2 5.7
F3SG-4RA1200-14 F3SG-2RA1200-14 119 1200 13 65 165 90 100 3.4 6.0
F3SG-4RA1280-14 F3SG-2RA1280-14 127 1280 13 65 165 95 100 3.6 6.4
F3SG-4RA1360-14 F3SG-2RA1360-14 135 1360 13 65 165 95 105 3.8 6.7
F3SG-4RA1440-14 F3SG-2RA1440-14 143 1440 18 90 190 85 105 4.0 7.0
F3SG-4RA1520-14 F3SG-2RA1520-14 151 1520 18 90 190 90 105 4.2 7.3
F3SG-4RA1600-14 F3SG-2RA1600-14 159 1600 18 90 190 90 110 4.4 7.6
F3SG-4RA1680-14 F3SG-2RA1680-14 167 1680 18 90 190 95 110 4.7 7.9
F3SG-4RA1760-14 F3SG-2RA1760-14 175 1760 18 90 190 100 115 4.9 8.2
F3SG-4RA1840-14 F3SG-2RA1840-14 183 1840 18 90 190 100 115 5.1 8.5
F3SG-4RA1920-14 F3SG-2RA1920-14 191 1920 18 90 190 105 120 5.3 8.8
F3SG-4RA2000-14 F3SG-2RA2000-14 199 2000 18 90 190 105 120 5.5 9.2
F3SG-4RA2080-14 F3SG-2RA2080-14 207 2080 18 90 190 110 125 5.7 9.5

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*3. The net weight is the weight of an emitter and a receiver.
*4. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

F3SG-4RA[][][][]-30/F3SG-2RA[][][][]-30

Model Num-
ber
of
Beams
Pro-
tective
Height
[mm]
Response Time
[ms] *1
Current
Consumption
[mA]
Weight
[kg]
ON

OFF
*2
OFF
(Syn-
chro-
nized)
→ ON
OFF
(Not
syn-
chro-
nized)
→ ON
Emitter Re-
ceiver
Net
*3
Gross
*4
F3SG-4RA0190-30 F3SG-2RA0190-30 8 190 8 40 140 35 75 0.6 2.1
F3SG-4RA0270-30 F3SG-2RA0270-30 12 270 8 40 140 35 75 0.9 2.4
F3SG-4RA0350-30 F3SG-2RA0350-30 16 350 8 40 140 40 75 1.1 2.7
F3SG-4RA0430-30 F3SG-2RA0430-30 20 430 8 40 140 45 75 1.3 3.0
F3SG-4RA0510-30 F3SG-2RA0510-30 24 510 8 40 140 50 75 1.5 3.3
F3SG-4RA0590-30 F3SG-2RA0590-30 28 590 8 40 140 50 75 1.7 3.6
F3SG-4RA0670-30 F3SG-2RA0670-30 32 670 8 40 140 55 75 1.9 3.9
F3SG-4RA0750-30 F3SG-2RA0750-30 36 750 8 40 140 60 80 2.1 4.2
F3SG-4RA0830-30 F3SG-2RA0830-30 40 830 8 40 140 65 80 2.3 4.5
F3SG-4RA0910-30 F3SG-2RA0910-30 44 910 13 65 165 50 80 2.5 4.8
F3SG-4RA0990-30 F3SG-2RA0990-30 48 990 13 65 165 50 80 2.7 5.1
F3SG-4RA1070-30 F3SG-2RA1070-30 52 1070 13 65 165 55 80 2.9 5.4
F3SG-4RA1150-30 F3SG-2RA1150-30 56 1150 13 65 165 55 85 3.1 5.7
F3SG-4RA1230-30 F3SG-2RA1230-30 60 1230 13 65 165 55 85 3.3 6.0
F3SG-4RA1310-30 F3SG-2RA1310-30 64 1310 13 65 165 60 85 3.5 6.3
F3SG-4RA1390-30 F3SG-2RA1390-30 68 1390 13 65 165 60 85 3.8 6.6
F3SG-4RA1470-30 F3SG-2RA1470-30 72 1470 13 65 165 65 85 4.0 6.9
F3SG-4RA1550-30 F3SG-2RA1550-30 76 1550 13 65 165 65 90 4.2 7.2
F3SG-4RA1630-30 F3SG-2RA1630-30 80 1630 13 65 165 70 90 4.4 7.5
F3SG-4RA1710-30 F3SG-2RA1710-30 84 1710 13 65 165 70 90 4.6 7.8
F3SG-4RA1790-30 F3SG-2RA1790-30 88 1790 13 65 165 70 90 4.8 8.1
F3SG-4RA1870-30 F3SG-2RA1870-30 92 1870 13 65 165 75 90 5.0 8.4
F3SG-4RA1950-30 F3SG-2RA1950-30 96 1950 13 65 165 75 95 5.2 8.7
F3SG-4RA2030-30 F3SG-2RA2030-30 100 2030 13 65 165 80 95 5.4 9.0
F3SG-4RA2110-30 F3SG-2RA2110-30 104 2110 13 65 165 80 95 5.6 9.3
F3SG-4RA2190-30 F3SG-2RA2190-30 108 2190 13 65 165 85 95 5.8 9.6
F3SG-4RA2270-30 F3SG-2RA2270-30 112 2270 13 65 165 85 100 6.0 9.9
F3SG-4RA2350-30 F3SG-2RA2350-30 116 2350 13 65 165 85 100 6.2 10.2
F3SG-4RA2430-30 F3SG-2RA2430-30 120 2430 13 65 165 90 100 6.4 10.5
F3SG-4RA2510-30 F3SG-2RA2510-30 124 2510 13 65 165 90 100 6.7 10.8

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*3. The net weight is the weight of an emitter and a receiver.
*4. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

Legislation and Standards

1. The F3SG-R does not receive type approval provided by Article 44-2 of the Industrial Safety and Health Act of Japan.
      When using the F3SG-R in Japan as a "safety system for pressing or shearing machines" prescribed in Article 42 of
      that law, the machine control system must receive type approval.

2. The F3SG-R is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery
     Directive Index Annex V, Item 2.

3. EU Declaration of Conformity
     OMRON declares that the F3SG-R is in conformity with the requirements of the following EU Directives:
     Machinery Directive 2006/42/EC
     EMC Directive 2014/30/EU

4. Conforming Standards
     (1) European standards
            EN61496-1 (Type 4 and Type 2 ESPE), EN 61496-2 (Type 4 and Type 2 AOPD), EN61508-1 through -4 (SIL 3 for
            Type 4 and SIL 1 for Type 2), EN ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
     (2) International standards
            IEC61496-1 (Type 4 and Type 2 ESPE), IEC61496-2 (Type 4 and Type 2 AOPD), IEC61508-1 through -4 (SIL 3 for
            Type 4 and SIL 1 for Type 2), ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
     (3) JIS standards
            JIS B 9704-1 (Type 4 and Type 2 ESPE), JIS B 9704-2 (Type 4 and Type 2 AOPD)
     (4) North American standards
            UL61496-1(Type 4 and Type 2 ESPE), UL61496-2(Type 4 and Type 2 AOPD), UL508, UL1998, CAN/CSA C22.2
            No.14, CAN/CSA C22.2 No.0.8
     (5) Chinese standards
            GB/T 4584(Specification of active opto-electronic protective devices for presses)

5. Third-Party Certifications
     (1) TÜV SÜD
            • EC Type-Examination certificate:
                EU Machinery Directive, Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN 61496-2)
            • Certificate:
                Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN61496-2), EN 61508-1 through -4 (SIL 3
                for Type 4 and SIL 1 for Type 2), EN ISO 13849-1:2015 (PL e, Category 4 for Type 4, and PL c, Category 2 for
                Type 2)
     (2) UL
            • UL Listing:
                Type 4 and Type 2 ESPE (UL61496-1), Type 4 and Type 2 AOPD (UL61496-2), UL508, UL1998, CAN/CSA C22.2
                No.14, CAN/CSA C22.2 No.0.8
     (3) China National Casting and Forging Machines Quality Supervision and Inspection Center
            • Certificate:
                GB/T 4584 (Specification of active opto-electronic protective devices for presses)

6. Other Standards
      The F3SG-R is designed according to the standards listed below. To make sure that the final system complies with
      the following standards and regulations, you are asked to design and use it in accordance with all other related
      standards, laws, and regulations. If you have any questions, consult with specialized organizations such as the body
      responsible for prescribing and/or enforcing machinery safety regulations in the location where the equipment is to
      be used.
       • European Standards: EN415-4, EN691-1, EN692, EN693, IEC 62046
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.212
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.217
       • American National Standards: ANSI B11.1 to B11.19
       • American National Standards: ANSI/RIA R15.06
       • Canadian Standards Association CSA Z142, Z432, Z434
       • SEMI Standards SEMI S2
       • Japan Ministry of Health, Labour and Welfare "Guidelines for Comprehensive Safety Standards of Machinery",
         Standard Bureau's Notification No. 0731001 dated July 31, 2007.rms and Conditions Agreement
       • Chinese National Standards: GB17120, GB27607

Indicator

Emitter

Name of Indicator Color Illuminated Blinking
Test TEST Green - External Test is being performed
Operating range LONG Green Long range mode is selected Lockout state due to DIP Switch setting error
or Operating range selection setting error
Power POWER Green Power is ON. Error due to noise
Lockout LOCKOUT Red - Lockout state due to error in emitter

Receiver

Name of Indicator Color Illuminated Blinking
Top-beam-state TOP Blue The top beam is unblocked Muting/Override state, or Lockout
state due to Cap error or Other sensor
error
PNP/NPN mode NPN Green NPN mode is selected by DIP Switch -
Response time SLOW Green Response Time Adjustment is enabled -
Sequence error SEQ Yellow - Sequence error in Muting or Pre-reset
mode
Blanking BLANK Green Blanking, Warning Zone or Reduced
Resolution is enabled
Teach-in mode, or Blanking
Monitoring error
Configuration CFG Green - Teach-in mode, zone measurement
beng performed by Dynamic Muting, or
Lockout state due to Parameter error
or Cascading Configuration error
Interlock INT-LK Yellow Interlock state Pre-reset mode
External device
monitoring
EDM Green RESET input is in ON state * Lockout state due to EDM error
Internal error INTERNAL Red - Lockout state due to Internal error, or
error due to abnormal power supply or
noise
Lockout LOCKOUT Red - Lockout state due to error in receiver
Stable-state STB Green Incident light level is 170% or higher
of ON-threshold
Safety output is instantaneously
turned OFF due to ambient light or
vibration
ON/OFF ON/OFF Green Safety output is in ON state -
Red Safety output is in OFF state, or the
sensor is in Setting state
Lockout state due to Safety Output
error, or error due to abnormal power
supply or noise
Communication COM Green Synchronization between emitter and
receiver is maintained
Lockout state due to Communication
error, or error due to abnormal power
supply or noise
Bottom-beam-
state
BTM Blue The bottom beam is unblocked Muting/Override state, or Lockout
state due to DIP Switch setting error

* The LED is illuminated when the EDM input is in ON state regardless of wiring with EDM used or unused.

Interface Unit

Main unit PC/AT compatible machine (computer that runs Microsoft Windows)
Operating system (OS) Windows 7 (32-bit/64-bit), Windows 8, 8.1 (32-bit/64-bit), Windows 10 (32-bit/64-bit)
Communication port USB port ×1
Ambient temperature Operating: -10 to 55°C, Storage: -30 to 70°C (non-icing and non-condensing)
Ambient humidity Operating: 35% to 85%, Storage: 35% to 95% (non-condensing)

Lamp

Item F39-LP
Applicable Sensor F3SG-[]RA/RR Series Safety Light Curtain (Receiver)
LED Light Color Red/Orange/Green
Power Supply Voltage 24 VDC±20%, ripple p-p 10% max. (shares sensor's power supply)
Current Consumption 25 mA max. (shares sensor's power supply.)
Ambient Temperature Operating: -10 to 55°C, Storage: -25 to 70°C
Ambient Humidity Operating: 35% to 85%, Storage: 35% to 95%
Vibration Resistance 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock Resistance 100 m/s2, 1000 shocks for all 3 axes
Degree of Protection IP65 and IP67 (When attached to F3SG)
Type of Connection Connectable to F3SG-RA's terminal connector
Material Lighting element: PC, Other body parts: PBT
Weight 45 g (when packaged)

F3SG-RR Robust type

Main unit

The [][][][] in the model names indicate the protective heights in millimeters.

F3SG-4RR[][][][]-14 F3SG-4RR[][][][]-25
Perfor-
mance
Object Resolution
(Detection Capability)
Opaque objects
14-mm dia. 25-mm dia.
Beam Gap 10 mm 20 mm
Number of Beams 23 to 191 12 to 96
Lens Size 5.2 × 3.4 (W × H) mm 6.0 × 5.0 (W × H) mm
Protective Height 240 to 1920 mm
Operating Range 0.3 to 10.0 m 0.3 to 17.0 m
Response
Time
ON to OFF Normal mode: 8 to 18 ms *1
Slow mode: 16 to 36 ms *1 *2
OFF to ON Normal mode: 40 to 90ms (synchronized), 140 to 190ms (not synchronized) *1
*1. Response time when used in one segment system or in cascaded connection.
Refer to "List of Models/Response Time/Current Consumption/Weight".
*2. Selectable by Configuration Tool.
Effective Aperture Angle
(EAA) (IEC 61496-2)
±2.5° max., emitter and receiver at operating range of 3 m or greater
Light Source Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time 2 s max.
Elec-
trical
Power Supply Voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption Refer to "List of Models/Response Time/Current Consumption/Weight".
Safety Outputs (OSSD) Two PNP or NPN transistor outputs
(PNP or NPN is selectable by Configuration Tool.)
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due to cable extension), Capacitive load of 1 μF max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor.
Auxiliary Output One PNP or NPN transistor output
(PNP or NPN is selectable by Configuration Tool.)
Load current of 100 mA max., Residual voltage of 2 V max .
Output
Operation
Mode
Safety
Output
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
Auxiliary
Output
Safety output (Inverted signal output:Enable) (default) (Cofigurable by Configuration Tool)
Input
Voltage
External
device
monitoring
input
(Lockout
reset
input)
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 8.0 mA) *
NPN
ON voltage: 0 V to 3 V (short circuit current: approx. 8.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 6.5 mA) *
Muting
input A/B
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 5.0 mA) *
NPN
ON voltage: 0 V to 3 V (short circuit current: approx. 5.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 3.0 mA) *
Test
input
24 V Active setting:
ON voltage: 9 V to Vs (short circuit current: approx. 2.5 mA) *
OFF voltage: 0 V to 3 V or open (short circuit current: approx. 2.0 mA)
0 V Active setting:
ON voltage: 0 V to 3 V (short circuit current: approx. 2.0 mA)
OFF voltage: 9 V to Vs or open (short circuit current: approx. 2.5 mA) *
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category
(IEC 60664-1)
II
Indicators Refer to "Indicator".
Protective Circuit Output short protection, Power supply reverse polarity protection
Insulation Resistance 20 MΩ or higher (500 VDC megger)
Dielectric Strength 1,000 VAC, 50/60 Hz (1 min)
Func-
tional
Mutual Interference Prevention (Scan Code) This function prevents mutual interference in up to two F3SG-RR systems.
Cascade Connection Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Cable length between sensors: 10 m max.
(not including cascading cable (F39-JGR2WTS) and power cable)
Test Function Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-Related Functions Interlock
External device monitoring (EDM)
Pre-reset
Fixed blanking/Floating blanking
Reduced resolution
Muting/Override
Scan code selection
PNP/NPN selection
Response time adjustment
Environ-
mental
Ambient
Temperature
Operating -10 to 55°C (14 to 131°F) (non-icing)
Storage -25 to 70°C (-13 to 158°F)
Ambient
Humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient Illuminance Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection
(IEC 60529)
IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G
Vibration Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y,and Z directions (no delay at resonant frequencies)
Shock Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total)
Pollution Degree
(IEC 60664-1)
Pollution Degree 3
Connec-
tions
Power
cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver. Cables prewired to the sensors.
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
*F3SG-RR meets the degree of protection when it is correctly connected with an F39-JD[][]RA-[] Oil-Resistant cable.
Number of Wires Emitter: 5, Receiver: 8
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending Radius
R36 mm
Cascading
cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver. IP67 rated when mated.
Number of Wires Emitter: 5, Receiver: 8
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending Radius
R5 mm
F39-JD[]RA-[]
Oil-Resistant
cable
- Single-
Ended Cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver. Cables prewired to the sensors.
IP67 and IP67G (JIS C 0920 Annex 1)* rated when mated.
* F3SG-RR meets the degree of protection when it is correctly connected with the power cable.
The degree of protection is not satisfied with the part where cable wires are uncovered.
Number of Wires Emitter: 5, Receiver: 8
Cable Length Refer to Lineup.
Cable Diameter 6 mm
Minimum
Bending Radius
R36 mm
Extension
cable
- Single-
Ended Cable
(F39-JD[]A)
- Double-
Ended Cable
(F39-JD[]B)
Type of
Connection
M12 connectors: 8-pin emitter and receiver. IP67 rated when mated.
Number of Wires Emitter: 8, Receiver: 8
Cable Length Refer to Lineup.
Cable Diameter 6.6 mm
Minimum
Bending Radius
R36 mm
Extension of Power Cable 100 m max. (Emitter/Receiver)
Material Material Housing: Aluminum alloy
Cap: PBT resin
Front window: Acrylic resin
Cable: Fluororesin
FE plate: Stainless steel
Weight Refer to "List of Models/Response Time/Current Consumption/Weight".
Included Accessories Safety Precautions,
Quick Installation Manual,
Troubleshooting Guide Sticker,
Warning Zone Label, End Cap
(for switching External Test Input function)
Con-
formity
Conforming standards Refer to "Legislation and Standards".
Performance Level (PL)/
Safety category
PL e/Category 4 (EN ISO 13849-1:2015)
PFHD 1.1 × 10-8 (IEC 61508)
Proof test interval TM Every 20 years (IEC 61508)
SFF 99% (IEC 61508)
HFT 1 (IEC 61508)
Classification Type B (IEC 61508-2)

Bluetooth Communication Unit

Communication System Bluetooth Version 3.0
Communication Profile SPP (Serial Port Profile)
Transmission Distance Approx. 10 m max. (Output power: Class 2) *

* It depends on use environment conditions.

List of Models/Response Time/Current Consumption/Weight

F3SG-4RR[][][][]-14

Model Num-
ber
of
Beams
Pro-
tective
Height
[mm]
(Overall
length)
Response Time [ms] *1 Current
Consumption [mA]
Weight
[kg]
ON

OFF
*2
OFF
(Syn-
chro-
nized)
→ ON
OFF
(Not
syn-
chro-
nized)
→ ON
Emitter Re-
ceiver
Net
*3
Gross
*4
F3SG-4RR0240-14 23 240 8 40 140 45 75 0.7 1.5
F3SG-4RR0320-14 31 320 8 40 140 55 75 0.9 1.7
F3SG-4RR0400-14 39 400 8 40 140 60 80 1.1 2.0
F3SG-4RR0480-14 47 480 13 65 165 50 80 1.3 2.3
F3SG-4RR0560-14 55 560 13 65 165 55 80 1.5 2.5
F3SG-4RR0640-14 63 640 13 65 165 60 85 1.7 2.8
F3SG-4RR0720-14 71 720 13 65 165 65 85 1.9 3.1
F3SG-4RR0800-14 79 800 13 65 165 65 90 2.1 3.4
F3SG-4RR0880-14 87 880 13 65 165 70 90 2.4 3.6
F3SG-4RR0960-14 95 960 13 65 165 75 90 2.6 3.9
F3SG-4RR1040-14 103 1040 13 65 165 80 95 2.8 4.2
F3SG-4RR1120-14 111 1120 13 65 165 85 95 3.0 4.4
F3SG-4RR1200-14 119 1200 13 65 165 90 100 3.2 4.7
F3SG-4RR1280-14 127 1280 13 65 165 95 100 3.4 5.0
F3SG-4RR1360-14 135 1360 13 65 165 95 105 3.6 5.3
F3SG-4RR1440-14 143 1440 18 90 190 85 105 3.8 5.5
F3SG-4RR1520-14 151 1520 18 90 190 90 105 4.0 5.8
F3SG-4RR1600-14 159 1600 18 90 190 90 110 4.2 6.1
F3SG-4RR1680-14 167 1680 18 90 190 95 110 4.4 6.3
F3SG-4RR1760-14 175 1760 18 90 190 100 115 4.6 6.6
F3SG-4RR1840-14 183 1840 18 90 190 100 115 4.8 6.9
F3SG-4RR1920-14 191 1920 18 90 190 105 120 5.0 7.2

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*3. The net weight is the weight of an emitter and a receiver.
*4. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

F3SG-4RR[][][][]-25

Model Num-
ber
of
Beams
Pro-
tective
Height
[mm]
(Overall
length)
Response Time [ms] *1 Current
Consumption [mA]
Weight
[kg]
ON

OFF
*2
OFF
(Syn-
chro-
nized)
→ ON
OFF
(Not
syn-
chro-
nized)
→ ON
Emitter Re-
ceiver
Net
*3
Gross
*4
F3SG-4RR0240-25 12 240 8 40 140 35 75 0.7 1.6
F3SG-4RR0320-25 16 320 8 40 140 40 75 0.9 1.9
F3SG-4RR0400-25 20 400 8 40 140 45 75 1.1 2.1
F3SG-4RR0480-25 24 480 8 40 140 50 75 1.3 2.4
F3SG-4RR0560-25 28 560 8 40 140 50 75 1.5 2.7
F3SG-4RR0640-25 32 640 8 40 140 55 75 1.7 3.0
F3SG-4RR0720-25 36 720 8 40 140 60 80 1.9 3.2
F3SG-4RR0800-25 40 800 8 40 140 65 80 2.1 3.5
F3SG-4RR0880-25 44 880 13 65 165 50 80 2.3 3.8
F3SG-4RR0960-25 48 960 13 65 165 50 80 2.5 4.0
F3SG-4RR1040-25 52 1040 13 65 165 55 80 2.7 4.3
F3SG-4RR1120-25 56 1120 13 65 165 55 85 2.9 4.6
F3SG-4RR1200-25 60 1200 13 65 165 55 85 3.1 4.9
F3SG-4RR1280-25 64 1280 13 65 165 60 85 3.3 5.1
F3SG-4RR1360-25 68 1360 13 65 165 60 85 3.5 5.4
F3SG-4RR1440-25 72 1440 13 65 165 65 85 3.7 5.7
F3SG-4RR1520-25 76 1520 13 65 165 65 90 3.9 5.9
F3SG-4RR1600-25 80 1600 13 65 165 70 90 4.1 6.2
F3SG-4RR1680-25 84 1680 13 65 165 70 90 4.3 6.5
F3SG-4RR1760-25 88 1760 13 65 165 70 90 4.5 6.7
F3SG-4RR1840-25 92 1840 13 65 165 75 90 4.7 7.0
F3SG-4RR1920-25 96 1920 13 65 165 75 95 4.9 7.3

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*3. The net weight is the weight of an emitter and a receiver.
*4. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

Legislation and Standards

1. The F3SG-RR does not receive type approval provided by Article 44-2 of the Industrial Safety and Health Act of Japan.
      When using the F3SG-RR in Japan as a "safety system for pressing or shearing machines" prescribed in Article 42 of
      that law, the machine control system must receive type approval.

2. The F3SG-RR is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery
      Directive Index Annex V, Item 2.

3. EC/EU Declaration of Conformity
      OMRON declares that the F3SG-RR is in conformity with the requirements of the following EC/EU Directives:
      Machinery Directive 2006/42/EC
      EMC Directive 2014/30/EU

4. Conforming Standards
     (1) European standards
            EN61496-1 (Type 4 ESPE), EN 61496-2 (Type 4 AOPD), EN61508-1 through -4 (SIL 3), EN ISO 13849-1:2015
            (PL e, Category 4)
     (2) International standards
            IEC61496-1 (Type 4 ESPE), IEC61496-2 (Type 4 AOPD), IEC61508-1 through -4 (SIL 3), ISO 13849-1:2015
            (PL e, Category 4)
     (3) JIS standards
            JIS B 9704-1 (Type 4 ESPE), JIS B 9704-2 (Type 4 AOPD)
     (4) North American standards
            UL61496-1 (Type 4 ESPE), UL61496-2 (Type 4 AOPD), UL508, UL1998,
            CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

5. Third-Party Certifications
     (1) TÜV SÜD
            • EC Type-Examination certificate:
                EU Machinery Directive, Type 4 ESPE (EN61496-1), Type 4 AOPD (EN 61496-2)
            • Certificate:
                Type 4 ESPE (EN61496-1), Type 4 AOPD (EN61496-2), EN 61508-1 through -4 (SIL 3), EN ISO 13849-1:2015
                (PL e, Category 4)
     (2) UL
            • UL Listing:
                Type 4 and ESPE (UL61496-1), Type 4 AOPD (UL61496-2), UL508, UL1998, CAN/CSA C22.2 No.14,
                CAN/CSA C22.2 No.0.8

6. Other Standards
      The F3SG-RR is designed according to the standards listed below. To make sure that the final system complies with the
      following standards and regulations, you are asked to design and use it in accordance with all other related standards,
      laws, and regulations. If you have any questions, consult with specialized organizations such as the body responsible
      for prescribing and/or enforcing machinery safety regulations in the location where the equipment is to be used.
       • European Standards: EN415-4, EN691-1, EN692, EN693, IEC 62046
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.212
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.217
       • American National Standards: ANSI B11.1 to B11.19
       • American National Standards: ANSI/RIA R15.06
       • Canadian Standards Association CSA Z142, Z432, Z434
       • SEMI Standards SEMI S2
       • Japan Ministry of Health, Labour and Welfare "Guidelines for Comprehensive Safety Standards of Machinery",
         Standard Bureau's Notification
         No. 0731001 dated July 31, 2007.rms and Conditions Agreement

Indicator

Emitter

Name of Indicator Color Illuminated Blinking
Test TEST Green - External Test is being performed
Operating range LONG Green Always illuminated Lockout state due to Scan code setting error
Power POWER Green Power is ON. Error due to noise
Lockout LOCKOUT Red - Lockout state due to error in emitter

Receiver

Name of Indicator Color Illuminated Blinking
Top-beam-state TOP Blue The top beam is unblocked Muting/Override state, or Lockout state due to Cap error or Other sensor error
PNP/NPN mode NPN Green NPN mode is selected -
Response time SLOW Green Response Time Adjustment is enabled -
Sequence error SEQ Yellow - Sequence error in Muting or Pre-reset mode
Blanking BLANK Green Blanking, Warning Zone or Reduced Resolution is enabled Blanking Monitoring error
Configuration CFG Green - Zone measurement being performed by Dynamic Muting, or Lockout state due to Parameter error or Cascading Configuration error
Interlock INT-LK Yellow Interlock state Pre-reset mode *2
External device monitoring EDM Green RESET input is in ON state *1 Lockout state due to EDM error
Internal error INTERNAL Red - Lockout state due to Internal error, or error due to abnormal power supply or noise
Lockout LOCKOUT Red - Lockout state due to error in receiver
Stable-state STB Green Incident light level is 170% or higher of ON-threshold Safety output is instantaneously turned OFF due to ambient light or vibration
ON/OFF ON/OFF Green Safety output is in ON state -
Red Safety output is in OFF state Lockout state due to Safety Output error, or error due to abnormal power supply or noise
Communication COM Green Synchronization between emitter and receiver is maintained Lockout state due to Communication error, or error due to abnormal power supply or noise
Bottom-beam-state BTM Blue The bottom beam is unblocked Muting/Override state, or Lockout state due to Scan code setting error

Note: TOP, CFG, LOCKOUT, STB and ON/OFF indicators are illuminated when the receiver of the F3SG-RR is in Setting mode.
*1. The EDM indicator is illuminated when the EDM input is in the ON state regardless of the use of the EDM function.
*2. Refer to Safety Light Curtain F3SG-[]RR Series User's Manual (ManNo.: Z383) for more information of blinking patterns.

Interface Unit

Main Unit PC/AT compatible machine (computer that runs Microsoft Windows)
Operating System (OS) Windows 7 (32-bit/64-bit), Windows 8, 8.1 (32-bit/64-bit), Windows 10 (32-bit/64-bit)
Communication Port USB port ×1
Ambient Temperature Operating: -10 to 55°C, Storage: -30 to 70°C (non-icing and non-condensing)
Ambient Humidity Operating: 35% to 85%, Storage: 35% to 95% (non-condensing)

Lamp

Item F39-LP
Applicable Sensor F3SG-[]RA/RR Series Safety Light Curtain (Receiver)
LED Light Color Red/Green/Orange
Power Supply Voltage 24 VDC±20%, ripple p-p 10% max. (shares sensor’s power supply)
Current Consumption 25 mA max. (shares sensor’s power supply.)
Ambient Temperature Operating: -10 to 55°C, Storage: -25 to 70°C
Ambient Humidity Operating: 35% to 85%, Storage: 35% to 95%
Vibration Resistance 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock Resistance 100 m/s2 , 1000 shocks for all 3 axes
Degree of Protection IP65 and IP67 (When attached to F3SG)
Type of Connection Connectable to F3SG-RA/RR’s terminal connector
Material Lighting element: PC, Other body parts: PBT
Weight 45 g (when packaged)

F3SG-RE Easy type

Main unit

The [][][][] in the model names indicate the protective heights in millimeters.

F3SG-4RE[][][][]-14
F3SG-2RE[][][][]-14
F3SG-4RE[][][][]-30
F3SG-2RE[][][][]-30
Perform-
ance
Type of ESPE
(IEC 61496-1)
Type 4 F3SG-4RE[][][][][]14/30
Type 2 F3SG-2RE[][][][][]14/30
Object Resolution
(Detection Capability)
Opaque objects
14-mm dia. 30-mm dia.
Beam Gap 10 mm 20 mm
Number of Beams 15 to 207 8 to 124
Lens Size 5.2 × 3.4 (W × H) mm 7-mm dia.
Protective Height 160 to 2080 mm (6.3 to 81.9 inch) 190 to 2510 mm (7.3 to 98.7 inch)
Operating
Range
Long 0.3 to 10.0 m (1 to 32 ft.) 0.3 to 20.0 m (1 to 65 ft.)
Short 0.3 to 3.0 m (1 to 10 ft.) 0.3 to 7.0 m (1 to 23 ft.)
Response
Time
ON to OFF 5 to 15 ms *1
OFF to ON 25 to 75 ms *1
*1.Response time when used in one segment system
Refer to "List of Models/Response Time/Current Consumption/Weight"
Effective
Aperture
Angle (EAA)
(IEC
61496-2)
Type 4 ±2.5° max., emitter and receiver at operating range of 3 m or greater
Type 2 ±5.0° max., emitter and receiver at operating range of 3 m or greater
Light Source Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time 2 s max.
Elec-
tricall
Power Supply Voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption Refer to "List of Models/Response Time/Current Consumption/Weight".
Safety Outputs (OSSD) F3SG-[]RE[][][][]P[][]: Two PNP transistor outputs
F3SG-[]RE[][][][]N[][]: Two NPN transistor outputs
Load current of 300 mA max., Residual voltage of 2 V max. (except for
voltage drop due to cable extension), Capacitive load of 1 μF max.,
Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1.The load inductance is the maximum value when the safety output
frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load
inductance becomes larger.
*2. These values must be taken into consideration when connecting
elements including a capacitive load such as a capacitor.
Output
Operation
Mode
Safety Output Light-ON (Safety output is enabled when the receiver receives an
emitting signal.)
Input
Voltage
Operating Range Select Input:
Long: 9 V to Vs (short circuit current: approx. 2.5 mA) *
Short: 0 to 3 V (short circuit current: approx. 2.0 mA)
The F3SG-RE enters the Long Mode when the Operating Range Select
Input line is open.
*The Vs indicates a supply voltage value in your environment.
Overvoltage Category
(IEC60664-1)
II
Indicators Refer to "LED Indicator Status".
Protective Circuit Output short protection, Power supply reverse polarity protection
Insulation Resistance 20 MΩ or higher (500 VDC megger)
Dielectric Strength 1,000 VAC, 50/60 Hz (1 min)
Func-
tional
Test Function Self-test (at power-on, and during operation)
Environ-
mental
Ambient
Temperature
Operating -10 to 55°C (14 to 131°F) (non-icing)
Storage -25 to 70°C (-13 to 158°F)
Ambient
Humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient Illuminance Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection
(IEC 60529)
IP65 and IP67
Vibration Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions
(no delay at resonant frequencies)
Shock Resistance (IEC 61496-1) Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total)
Pollution Degree (IEC 60664-1) Pollution Degree 3
Connec-
tions
Power cable Type of
Connection
M12 connectors: 4-pin, IP67 rated when mated,Cables prewired to the
sensors
Number of Wires Emitter: 4, Receiver: 4
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending Radius
R5 mm
Extension
cable
- Single-
Ended Cable
- Double-
Ended Cable
Type of
Connection
Use the XS5[]-D42[] series cables.
Number of Wires
Cable Length
Cable Diameter
Minimum
Bending Radius
Extension of Power Cable 100 m max.
Material Material Housing: Aluminum alloy
Cap: PBT resin
Front window: Acrylic resin
Cable: Oil-resistant PVC resin
Standard Fixed Bracket (F39-LGF): Zinc alloy
FE plate: Stainless steel
Weight Refer to "List of Models/Response Time/Current Consumption/Weight".
Included Accessories Safety Precautions, Quick Installation Manual, Standard Fixed Bracket*1,
Troubleshooting Guide Sticker
*1. The quantity of Standard Fixed Brackets included varies depending
on the protective height.
[F3SG-[]RE[][][][][]14]
- Protective height of 0160 to 1200: 2 sets
- Protective height of 1280 to 2080: 3 sets
[F3SG-[]RE[][][][][]30]
- Protective height of 0190 to 1230: 2 sets
- Protective height of 1310 to 2270: 3 sets
- Protective height of 2350 to 2510: 4 sets
Con-
formity
Conforming standards Refer to "Legislation and Standards".
Performance
Level (PL)/
Safety
category
Type 4 PL e/Category 4 (EN ISO 13849-1:2015)
Type 2 PL c/Category 2 (EN ISO 13849-1:2015)
PFHD 9.1 × 10-9 (IEC 61508)
Proof test interval TM Every 20 years (IEC 61508)
SFF 99% (IEC 61508)
HFT 1 (IEC 61508)
Classification Type B (IEC 61508-2)

List of Models/Response Time/Current Consumption/Weight

F3SG-[]RE[][][][][]-14

Model Number
of
Beams
Protective
Height
[mm]
Response Time
[ms] *1
Current
Consumption [mA]
Weight
[kg]
ON

OFF
OFF
(Syn-
chronized)
→ ON
OFF
(Not syn-
chronized)
→ ON
Emitter Receiver Net
*2
Gross
*3
F3SG-[]RE0160[]14 15 160 5 25 125 45 50 0.6 1.9
F3SG-[]RE0240[]14 23 240 5 25 125 55 55 0.8 2.2
F3SG-[]RE0320[]14 31 320 7 35 135 55 55 1.0 2.5
F3SG-[]RE0400[]14 39 400 7 35 135 65 60 1.2 2.9
F3SG-[]RE0480[]14 47 480 7 35 135 70 60 1.4 3.2
F3SG-[]RE0560[]14 55 560 7 35 135 80 60 1.6 3.5
F3SG-[]RE0640[]14 63 640 7 35 135 85 65 1.9 3.8
F3SG-[]RE0720[]14 71 720 9 45 145 80 65 2.1 4.1
F3SG-[]RE0800[]14 79 800 9 45 145 85 70 2.3 4.4
F3SG-[]RE0880[]14 87 880 9 45 145 90 70 2.5 4.7
F3SG-[]RE0960[]14 95 960 9 45 145 95 75 2.7 5.0
F3SG-[]RE1040[]14 103 1040 9 45 145 100 75 2.9 5.4
F3SG-[]RE1120[]14 111 1120 11 55 155 90 75 3.1 5.7
F3SG-[]RE1200[]14 119 1200 11 55 155 95 80 3.3 6.0
F3SG-[]RE1280[]14 127 1280 11 55 155 100 80 3.5 6.3
F3SG-[]RE1360[]14 135 1360 11 55 155 105 85 3.7 6.6
F3SG-[]RE1440[]14 143 1440 11 55 155 110 85 3.9 6.9
F3SG-[]RE1520[]14 151 1520 13 65 165 100 90 4.1 7.2
F3SG-[]RE1600[]14 159 1600 13 65 165 105 90 4.4 7.5
F3SG-[]RE1680[]14 167 1680 13 65 165 110 95 4.6 7.9
F3SG-[]RE1760[]14 175 1760 13 65 165 115 95 4.8 8.2
F3SG-[]RE1840[]14 183 1840 13 65 165 115 95 5.0 8.5
F3SG-[]RE1920[]14 191 1920 15 75 175 110 100 5.2 8.8
F3SG-[]RE2000[]14 199 2000 15 75 175 115 100 5.4 9.1
F3SG-[]RE2080[]14 207 2080 15 75 175 115 105 5.6 9.4

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The net weight is the weight of an emitter and a receiver.
*3. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

F3SG-[]RE[][][][][]30

Model Number
of
Beams
Protective
Height
[mm]
Response Time
[ms] *1
Current
Consumption [mA]
Weight
[kg]
ON

OFF
OFF
(Syn-
chronized)
→ ON
OFF
(Not syn-
chronized)
→ ON
Emitter Receiver Net
*2
Gross
*3
F3SG-[]RE0190[]30 8 190 5 25 125 40 50 0.6 2.0
F3SG-[]RE0270[]30 12 270 5 25 125 45 50 0.8 2.3
F3SG-[]RE0350[]30 16 350 5 25 125 50 50 1.0 2.6
F3SG-[]RE0430[]30 20 430 5 25 125 55 55 1.2 2.9
F3SG-[]RE0510[]30 24 510 5 25 125 60 55 1.4 3.2
F3SG-[]RE0590[]30 28 590 7 35 135 50 55 1.6 3.5
F3SG-[]RE0670[]30 32 670 7 35 135 55 55 1.8 3.8
F3SG-[]RE0750[]30 36 750 7 35 135 60 60 2.0 4.1
F3SG-[]RE0830[]30 40 830 7 35 135 65 60 2.2 4.4
F3SG-[]RE0910[]30 44 910 7 35 135 65 60 2.4 4.7
F3SG-[]RE0990[]30 48 990 7 35 135 70 60 2.6 5.0
F3SG-[]RE1070[]30 52 1070 7 35 135 75 60 2.8 5.3
F3SG-[]RE1150[]30 56 1150 7 35 135 80 65 3.0 5.6
F3SG-[]RE1230[]30 60 1230 7 35 135 85 65 3.3 5.9
F3SG-[]RE1310[]30 64 1310 7 35 135 85 65 3.5 6.2
F3SG-[]RE1390[]30 68 1390 9 45 145 75 65 3.7 6.5
F3SG-[]RE1470[]30 72 1470 9 45 145 80 65 3.9 6.8
F3SG-[]RE1550[]30 76 1550 9 45 145 80 70 4.1 7.1
F3SG-[]RE1630[]30 80 1630 9 45 145 85 70 4.3 7.4
F3SG-[]RE1710[]30 84 1710 9 45 145 85 70 4.5 7.7
F3SG-[]RE1790[]30 88 1790 9 45 145 90 70 4.7 8.0
F3SG-[]RE1870[]30 92 1870 9 45 145 95 75 4.9 8.3
F3SG-[]RE1950[]30 96 1950 9 45 145 95 75 5.1 8.6
F3SG-[]RE2030[]30 100 2030 9 45 145 100 75 5.3 8.9
F3SG-[]RE2110[]30 104 2110 9 45 145 100 75 5.5 9.2
F3SG-[]RE2190[]30 108 2190 11 55 155 90 75 5.7 9.5
F3SG-[]RE2270[]30 112 2270 11 55 155 95 80 5.9 9.8
F3SG-[]RE2350[]30 116 2350 11 55 155 95 80 6.1 10.1
F3SG-[]RE2430[]30 120 2430 11 55 155 95 80 6.3 10.4
F3SG-[]RE2510[]30 124 2510 11 55 155 100 80 6.5 10.7

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The net weight is the weight of an emitter and a receiver.
*3. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

Legislation and Standards

For F3SG-RE laws, regulations, and standards, refer to F3SG-RA datasheet Legislation and Standards on Catalog.

LED Indicator Status

Emitter

Name of Indicator Color Illuminated Blinking
Operating range LONG Green Long range mode is selected Lockout state due to Operating range selection
setting error
Power POWER Green Power is ON. Error due to noise
Lockout LOCKOUT Red - Lockout state due to error in emitter

Receiver

Name of Indicator Color Illuminated Blinking
Top-beam-state TOP Blue The top beam is unblocked -
Internal error INTERNAL Red - Lockout state due to Internal error, or error
due to abnormal power supply or noise
Lockout LOCKOUT Red - Lockout state due to error in receiver
Stable-state STB Green Incident light level is 170% or
higher of ON threshold
Safety output is instantaneously turned OFF
due to ambient light or vibration
ON/OFF ON/OFF Green Safety output is in ON state -
Red Safety output is in OFF state Lockout state due to Safety Output error, or
error due to abnormal power supply or noise
Communication COM Green Synchronization between emitter
and receiver is maintained
Lockout state due to Communication error,
or error due to abnormal power supply or
noise
Bottom-beam-
state
BTM Blue The bottom beam is unblocked -

F3SG-RA-01TS

Main unit

The [][][][] in the model names indicate the protective heights in millimeters.

F3SG-4RA[][][][]-25-01TS
Perform-
ance
Object Resolution
(Detection Capability)
Opaque objects
25-mm dia.
Beam Gap 20 mm
Number of Beams 8 to 96
Lens Size 6.0×5.0 (W×H) mm
Protective Height 185 to 1945 mm (7.3 to 76.6 inch)
Operating
Range
Long 0.3 to 17.0 m (1 to 56 ft.)
Short 0.3 to 5.0 m (1 to 16 ft.)
Response
Time
ON to OFF 8 to 13 ms *1
OFF to ON 40 to 65ms *1
*1.Response time when used in one segment system or in cascaded connection.
Refer to the one segment system. Refer to Safety Light Curtain
F3SG-4RA[][][][]-25-01TS Series User's Manual (ManNo.: Z380) for cascaded connection
Effective
Aperture
Angle (EAA)
(IEC
61496-2)
Type 4 ±2.5° max., emitter and receiver at operating range of 3 m or greater
Light Source Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time 2 s max.
Elec-
trical
Power Supply Voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption Refer to "List of Models/Response Time/Current Consumption/Weight".
Safety Outputs (OSSD) Two PNP or NPN transistor outputs (PNP or NPN is selectable by DIP Switch.)
Load current of 300 mA max., Residual voltage of 2 V max.
(except for voltage drop due to cable extension), Capacitive load of 1 μF
max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2

*1.*The load inductance is the maximum value when the safety output
frequently repeats ON and OFF. When you use the safety output at 4 Hz
or less, the usable load inductance becomes larger.
*2.*These values must be taken into consideration when connecting
elements including a capacitive load such as a capacitor.
Auxiliary Output One PNP or NPN transistor output (Safety Output and homopolarity) Load
current of 100 mA max., Residual voltage of 2 V max .
Output
Operation
Mode
Safety Output Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
Auxiliary Output Reverse output of safety output
Input
Voltage
External device
monitoring input
(Lockout reset
input)
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 8.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 8.0 mA) *
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 6.5 mA) *
Test input 24 V inactive setting
ON voltage: 0 to 3 V or open (short circuit current: approx. 2.0 mA)
OFF voltage: 9 V to Vs (short circuit current: approx. 2.5 mA) *
0 V inactive setting
ON voltage: 9 V to Vs or open (short circuit current: approx. 2.5 mA)
OFF voltage: 0 to 3 V (short circuit current: approx. 2.0 mA)
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category
(IEC 60664-1)
II
Indicators Refer to "Indicator".
Protective Circuit Output short protection, Power supply reverse polarity protection
Insulation Resistance 20 MΩ or higher (500 VDC megger)
Dielectric Strength 1,000 VAC, 50/60 Hz (1 min)
Func-
tional
Mutual Interference
Prevention (Scan Code)
This function prevents mutual interference in up to two F3SG-RA systems.
Cascade Connection Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Cable length between sensors: 10 m max.
(not including cascading cable (F39-JGR2WTS) and power cable)
Test Function Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-Related Functions External device monitoring (EDM)
Scan code selection
PNP/NPN selection
Environ-
mental
Ambient
Temperature
Operating -10 to 55°C (14 to 131°F) (non-icing)
Storage -25 to 70°C (-13 to 158°F)
Ambient
Humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient Illuminance Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection
(IEC 60529)
IP65 and IP67
Vibration Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in
X, Y, and Z directions (no delay at resonant frequencies)
Shock Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z
directions (600 shocks in total)
Pollution Degree
(IEC 60664-1)
Pollution Degree 3
Connec-
tions
Power cable Type of
Connection
M12 connectors: 8-pin emitter and receiver, IP67 rated when mated,
Cables pre-wired to the sensors
Number of Wires On emitter: 5-wire, On receiver: 8-wire
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending Radius
R5 mm
Cascading
cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver, IP67 rated when mated
Number of Wires On emitter: 5-wire, On receiver: 8-wire
Cable Length 0.2 m
Cable Diameter 6 mm
Minimum
Bending Radius
R5 mm
Extension
cable
- Single-
Ended Cable
- Double-
Ended Cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver, IP67 rated when mated
Number of Wires On emitter and receiver: 8-wire
Cable Length Refer to Lineup.
Cable Diameter 6.6 mm
Minimum
Bending Radius
R36 mm
Extension of Power Cable 100 m max.(Emitter/Receiver)
Material Material Housing: Aluminum alloy
Cap: PBT resin
Front window: Acrylic resin
Cable: Oil-resistant PVC resin
FE plate: Stainless steel
Weight Refer to "List of Models/Response Time/Current Consumption/Weight".
Included Accessories Safety Precautions, Quick Installation Manual, Troubleshooting Guide
Sticker,
Con-
formity
Conforming standards Refer to "Legislation and Standards".
Type of ESPE (IEC 61496-1) Type 4
Performance Level (PL)/
Safety category
PL e/Category 4 (EN ISO 13849-1:2015)
PFHD 1.1 × 10-8 (IEC 61508)
Proof test interval TM Every 20 years (IEC 61508)
SFF 99% (IEC 61508)
HFT 1 (IEC 61508)
Classification Type B (IEC 61508-2)

Bluetooth Communication Unit

Communication System Bluetooth Version 3.0
Communication Profile SPP (Serial Port Profile)
Transmission Distance Approx. 10 m max. (Output power: Class 2) *

* It depends on use environment conditions.

List of Models/Response Time/Current Consumption/Weight

Model Number
of
Beams
Pro-
tective
Height
[mm]
Response Time [ms] *1 Current
Consumption
[mA]
Weight
[kg]
ON →
OFF
*2
OFF (Syn-
chronized)
→ ON
OFF (Not
synchro-
nized)
→ ON
Emitter Receiver Net
*3
Gross
*4
F3SG-4RA0185-25-01TS 8 185 8 40 140 35 75 0.7 1.4
F3SG-4RA0265-25-01TS 12 265 8 40 140 35 75 0.9 1.6
F3SG-4RA0345-25-01TS 16 345 8 40 140 40 75 1.1 1.9
F3SG-4RA0425-25-01TS 20 425 8 40 140 45 75 1.3 2.2
F3SG-4RA0505-25-01TS 24 505 8 40 140 50 75 1.5 2.5
F3SG-4RA0585-25-01TS 28 585 8 40 140 50 75 1.7 2.7
F3SG-4RA0665-25-01TS 32 665 8 40 140 55 75 1.9 3.0
F3SG-4RA0745-25-01TS 36 745 8 40 140 60 80 2.1 3.3
F3SG-4RA0825-25-01TS 40 825 8 40 140 65 80 2.3 3.6
F3SG-4RA0905-25-01TS 44 905 13 65 165 50 80 2.5 3.8
F3SG-4RA0985-25-01TS 48 985 13 65 165 50 80 2.8 4.1
F3SG-4RA1065-25-01TS 52 1065 13 65 165 55 80 3.0 4.4
F3SG-4RA1145-25-01TS 56 1145 13 65 165 55 85 3.2 4.7
F3SG-4RA1225-25-01TS 60 1225 13 65 165 55 85 3.4 5.0
F3SG-4RA1305-25-01TS 64 1305 13 65 165 60 85 3.6 5.2
F3SG-4RA1385-25-01TS 68 1385 13 65 165 60 85 3.8 5.5
F3SG-4RA1465-25-01TS 72 1465 13 65 165 65 85 4.0 5.8
F3SG-4RA1545-25-01TS 76 1545 13 65 165 65 90 4.2 6.0
F3SG-4RA1625-25-01TS 80 1625 13 65 165 70 90 4.4 6.3
F3SG-4RA1705-25-01TS 84 1705 13 65 165 70 90 4.6 6.6
F3SG-4RA1785-25-01TS 88 1785 13 65 165 70 90 4.9 6.9
F3SG-4RA1865-25-01TS 92 1865 13 65 165 75 90 5.1 7.1
F3SG-4RA1945-25-01TS 96 1945 13 65 165 75 95 5.3 7.4

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*3. The net weight is the weight of an emitter and a receiver.
*4. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

Legislation and Standards

1. The F3SG-RA-01TS does not receive type approval provided by Article 44-2 of the Industrial Safety and Health Act of
      Japan. When using the F3SG-RA-01TS in Japan as a "safety system for pressing or shearing machines" prescribed in
      Article 42 of that law, the machine control system must receive type approval.

2. The F3SG-RA-01TS is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery
     Directive Index Annex V, Item 2.

3. EU Declaration of Conformity
     OMRON declares that the F3SG-RA-01TS is in conformity with the requirements of the following EU Directives:
     Machinery Directive 2006/42/EC
     EMC Directive 2014/30/EU

4. Conforming Standards
     (1) European standards
            EN61496-1 (Type 4 and Type 2 ESPE), EN 61496-2 (Type 4 and Type 2 AOPD), EN61508-1 through -4 (SIL 3 for
            Type 4 and SIL 1 for Type 2), EN ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
     (2) International standards
            IEC61496-1 (Type 4 and Type 2 ESPE), IEC61496-2 (Type 4 and Type 2 AOPD), IEC61508-1 through -4 (SIL 3 for
            Type 4 and SIL 1 for Type 2), ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
     (3) JIS standards
            JIS B 9704-1 (Type 4 and Type 2 ESPE), JIS B 9704-2 (Type 4 and Type 2 AOPD)
     (4) North American standards
            UL61496-1(Type 4 and Type 2 ESPE), UL61496-2(Type 4 and Type 2 AOPD), UL508, UL1998,
            CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

5. Third-Party Certifications
     (1) TÜV SÜD
            • EC Type-Examination certificate:
                EU Machinery Directive, Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN 61496-2)
            • Certificate:
                Type 4 and Type 2 ESPE (EN61496-1), Type 4 and Type 2 AOPD (EN61496-2), EN 61508-1 through -4 (SIL 3
                for Type 4 and SIL 1 for Type 2), EN ISO 13849-1:2015 (PL e, Category 4 for Type 4, and PL c, Category 2 for
                Type 2)
     (2) UL
            • UL Listing:
                Type 4 and Type 2 ESPE (UL61496-1), Type 4 and Type 2 AOPD (UL61496-2), UL508, UL1998, CAN/CSA C22.2
                No.14, CAN/CSA C22.2 No.0.8

6. Other Standards
      The F3SG-RA-01TS is designed according to the standards listed below. To make sure that the final system complies
      with the following standards and regulations, you are asked to design and use it in accordance with all other related
      standards, laws, and regulations. If you have any questions, consult with specialized organizations such as the body
      responsible for prescribing and/or enforcing machinery safety regulations in the location where the equipment is to
      be used.
       • European Standards: EN415-4, EN691-1, EN692, EN693, IEC 62046
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.212
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.217
       • American National Standards: ANSI B11.1 to B11.19
       • American National Standards: ANSI/RIA R15.06
       • Canadian Standards Association CSA Z142, Z432, Z434
       • SEMI Standards SEMI S2
       • Japan Ministry of Health, Labour and Welfare "Guidelines for Comprehensive Safety Standards of Machinery",
         Standard Bureau's Notification No. 0731001 dated July 31, 2007.rms and Conditions Agreement

Indicator

Emitter

Name of
Indicator
Color Illuminated Blinking
TEST Green - External Test is being performed
LONG Green Long range mode
is selected
Lockout state due to DIP Switch setting error or
Operating range selection setting error
POWER Green Power is ON. Error due to noise
LOCKOUT Red - Lockout state due to error in emitter

Receiver

Name of
Indicator
Color Illuminated Blinking
TOP Blue The top beam is unblocked Lockout state due to Cap error or Other sensor error
NPN Green NPN mode is selected by
DIP Switch
-
CFG Green - Lockout state due to Cascading Configuration error
EDM Green EDM input is in ON state * Lockout state due to EDM error
INTERNAL Red - Lockout state due to Internal error,
or error due to abnormal power supply or noise
LOCKOUT Red - Lockout state due to error in receiver
STB Green Incident light level is 170% or
higher of ON-threshold
Safety output is instantaneously turned OFF
due to ambient light or vibration.
ON/OFF Green Safety output is in ON state -
Red Safety output is in OFF state Lockout state due to Safety Output error,
or error due to abnormal power supply or noise
COM Green Synchronization between
emitter and receiver is
maintained
Lockout state due to Communication error,
or error due to abnormal power supply or noise
BTM Blue The bottom beam is unblocked Lockout state due to DIP Switch setting error

* The LED is illuminated when the EDM input is in ON state regardless of wiring with EDM used or unused.

Interface Unit

Main unit PC/AT compatible machine (computer that runs Microsoft Windows)
Operating system (OS) Windows 7 (32-bit/64-bit), Windows 8, 8.1 (32-bit/64-bit), Windows 10 (32-bit/64-bit)
Communication port USB port ×1
Ambient temperature Operating: -10 to 55°C, Storage: -30 to 70°C(non-icing and non-condensing)
Ambient humidity Operating: 35% to 85%, Storage: 35% to 95%(non-condensing)

Lamp

Item F39-LP
Applicable Sensor F3SG-[]RA Series Safety Light Curtain (Receiver)
LED Light Color Red/Orange/Green
Power Supply Voltage 24 VDC±20%, ripple p-p 10% max.(shares sensor's power supply)
Current Consumption 25 mA max. (shares sensor′s power supply.)
Ambient Temperature Operating: -10 to 55°C, Storage: -25 to 70°C
Ambient Humidity Operating: 35% to 85%, Storage: 35% to 95%
Vibration Resistance 10 to 55 Hz, Multiple amplitude of 0.7 mm,20 sweeps for all 3 axes
Shock Resistance 100 m/s2 , 1000 shocks for all 3 axes
Degree of Protection IP65 and IP67(When attached to F3SG)
Type of Connection Connectable to F3SG-RA's terminal connector
Material Lighting element: PC, Other body parts: PBT
Weight 45 g (when packaged)

F3SG-RA-02TS

Main unit

The [][][][] in the model names indicate the protective heights in millimeters.

F3SG-4RA[][][][]-25-02TS
Perform-
ance
Object Resolution
(Detection Capability)
Opaque objects
25-mm dia.
Beam Gap 20 mm
Number of Beams 12 to 96
Lens Size 6.0 × 5.0 (W × H) mm
Protective Height 240 to 1920 mm
Operating Range 0.3 to 17.0 m
Response
Time
ON to OFF Normal mode: 8 to 13 ms *1
OFF to ON Normal mode: 40 to 90ms (synchronized), 140 to 190ms (not
synchronized) *1
*1.Response time when used in one segment system or in cascaded connection.
Refer to the one segment system. Refer to Safety Light Curtain
F3SG-4RA[][][][]-25-02TS Series User's Manual (ManNo.: Z391) for cascaded connection.
EffectiveApertureAngle
(EAA) (IEC 61496-2)
±2.5° max., emitter and receiver at operating range of 3 m or greater
Light Source Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time 2 s max.
Elec-
trical
Power Supply Voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption Refer to "List of Models/Response Time/Current Consumption/Weight".
Safety Outputs (OSSD) Two PNP transistor outputs
Load current of 300 mA max., Residual voltage of 2 V max.
(except for voltage drop due to cable extension),
Capacitive load of 1 μF max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max.

*1. The load inductance is the maximum value when the safety output
frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load
inductance becomes larger.
*2. These values must be taken into consideration when connecting
elements including a capacitive load such as a capacitor.
Auxiliary Output One PNP transistor output
Load current of 100 mA max., Residual voltage of 2 V max .
Output
Operation
Mode
Safety Output Light-ON (Safety output is enabled when the receiver receives an
emitting signal.)
Auxiliary Output Reverse output of safety output
Input
Voltage
External device
monitoring
input
(Lockout
reset input)
ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 8.0 mA) *
Test input 24 V Active setting:
ON voltage: 9 V to Vs (short circuit current: approx. 2.5 mA) *
OFF voltage: 0 V to 3 V or open (short circuit current: approx. 2.0 mA)
0 V Active setting:
ON voltage: 0 V to 3 V (short circuit current: approx. 2.0 mA)
OFF voltage: 9 V to Vs or open (short circuit current: approx. 2.5 mA) *
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category
(IEC 60664-1)
II
Indicators Refer to "Indicator".
Protective Circuit Output short protection, Power supply reverse polarity protection
Insulation Resistance 20 MΩ or higher (500 VDC megger)
Dielectric Strength 1,000 VAC, 50/60 Hz (1 min)
Func-
tional
Mutual Interference
Prevention (Scan Code)
This function prevents mutual interference in up to two F3SG-RA-25-02TS systems.
Cascade Connection Number of cascaded segments: 3 max.
(only among F3SG-4RA[][][][]-25-02TS's)
Total number of beams: 255 max.
Cable length between sensors: 10 m max.
(not including cascading cable (F39-JGR2WTS) and power cable)
Test Function Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-Related Functions External device monitoring (EDM)
Scan code selection
Environ-
mental
Ambient
Temperature
Operating -10 to 55°C (14 to 131°F) (non-icing)
Storage -25 to 70°C (-13 to 158°F)
Ambient
Humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient Illuminance Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection
(IEC 60529)
IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G
Vibration Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies)
Shock Resistance
(IEC 61496-1)
Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total)
Pollution Degree
(IEC 60664-1)
Pollution Degree 3
Connec-
tions
Power cable Type of
Connection
M12 connectors: 8-pin emitter and receiver. Cables prewired to the sensors.
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
* F3SG-RA-25-02TS meets the degree of protection when it is correctly
connected withan F39-JD[][]RA-[] Oil-Resistant extension cable.
Number of
Wires
Emitter: 5, Receiver: 8
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending
Radius
R36 mm
Cascading
cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver. IP67 rated when mated.
Number of
Wires
Emitter: 5, Receiver: 8
Cable Length 0.3 m
Cable Diameter 6 mm
Minimum
Bending
Radius
R5 mm
F39-JD[]RA-[]
Oil-
Resistant
cable
- Single-
Ended Cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver. Cables prewired to the sensors.
IP67 and IP67G (JIS C 0920 Annex 1)* rated when mated.
* F3SG-RA-25-02TS meets the degree of protection when it is correctly
connected with the power cable.
The degree of protection is not satisfied with the part where cable wires
are uncovered.
Number of
Wires
Emitter: 5, Receiver: 8
Cable Length Refer to Lineup.
Cable Diameter 6 mm
Minimum
Bending
Radius
R36 mm
Extension
cable
- Single-
Ended Cable
(F39-JD[]A)
- Double-
Ended Cable
(F39-JD[]B)
Type of
Connection
M12 connectors: 8-pin emitter and receiver. IP67 rated when mated.
Number of
Wires
Emitter: 8, Receiver: 8
Cable Length Refer to Lineup.
Cable Diameter 6.6 mm
Minimum
Bending
Radius
R36 mm
Extension of Power Cable 100 m max. (Emitter/Receiver)
Material Material Housing: Aluminum alloy
Cap: PBT resin
Front window: Acrylic resin
Cable: Fluororesin
FE plate: Stainless steel
Weight Refer to "List of Models/Response Time/Current Consumption/Weight".
Included Accessories Safety Precautions, Quick Installation Manual, Troubleshooting Guide Sticker,
End Cap (for switching External Test Input function)
Con-
formity
Conforming standards Refer to "Legislation and Standards".
Performance Level (PL)/
Safety category
PL e/Category 4 (EN ISO 13849-1:2015)
PFHD 1.1 × 10-8 (IEC 61508)
Proof test interval TM Every 20 years (IEC 61508)
SFF 99% (IEC 61508)
HFT 1 (IEC 61508)
Classification Type B (IEC 61508-2)

Bluetooth Communication Unit

Communication System Bluetooth Version 3.0
Communication Profile SPP (Serial Port Profile)
Transmission Distance Approx. 10 m max. (Output power: Class 2) *

* It depends on use environment conditions.

List of Models/Response Time/Current Consumption/Weight

Model Number
of
Beams
Pro-
tective
Height
[mm]
Response Time [ms] *1 Current
Consumption
[mA]
Weight
[kg]
ON →
OFF
*2
OFF (Syn-
chronized)
→ ON
OFF (Not
synchro-
nized)
→ ON
Emitter Receiver Net
*3
Gross
*4
F3SG-4RA0240-25-02TS 12 240 8 40 140 35 75 0.7 1.6
F3SG-4RA0320-25-02TS 16 320 8 40 140 40 75 0.9 1.9
F3SG-4RA0400-25-02TS 20 400 8 40 140 45 75 1.1 2.1
F3SG-4RA0480-25-02TS 24 480 8 40 140 50 75 1.3 2.4
F3SG-4RA0560-25-02TS 28 560 8 40 140 50 75 1.5 2.7
F3SG-4RA0640-25-02TS 32 640 8 40 140 55 75 1.7 3.0
F3SG-4RA0720-25-02TS 36 720 8 40 140 60 80 1.9 3.2
F3SG-4RA0800-25-02TS 40 800 8 40 140 65 80 2.1 3.5
F3SG-4RA0880-25-02TS 44 880 13 65 165 50 80 2.3 3.8
F3SG-4RA0960-25-02TS 48 960 13 65 165 50 80 2.5 4.0
F3SG-4RA1040-25-02TS 52 1040 13 65 165 55 80 2.7 4.3
F3SG-4RA1120-25-02TS 56 1120 13 65 165 55 85 2.9 4.6
F3SG-4RA1200-25-02TS 60 1200 13 65 165 55 85 3.1 4.9
F3SG-4RA1280-25-02TS 64 1280 13 65 165 60 85 3.3 5.1
F3SG-4RA1360-25-02TS 68 1360 13 65 165 60 85 3.5 5.4
F3SG-4RA1440-25-02TS 72 1440 13 65 165 65 85 3.7 5.7
F3SG-4RA1520-25-02TS 76 1520 13 65 165 65 90 3.9 5.9
F3SG-4RA1600-25-02TS 80 1600 13 65 165 70 90 4.1 6.2
F3SG-4RA1680-25-02TS 84 1680 13 65 165 70 90 4.3 6.5
F3SG-4RA1760-25-02TS 88 1760 13 65 165 70 90 4.5 6.7
F3SG-4RA1840-25-02TS 92 1840 13 65 165 75 90 4.7 7.0
F3SG-4RA1920-25-02TS 96 1920 13 65 165 75 95 4.9 7.3

*1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
*2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than these values.
*3. The net weight is the weight of an emitter and a receiver.
*4. The gross weight is the weight of an emitter, a receiver, included accessories and a package.

Legislation and Standards

1. The F3SG-RA-02TS does not receive type approval provided by Article 44-2 of the Industrial Safety and Health Act of
     Japan. When using the F3SG-RA-02TS in Japan as a "safety system for pressing or shearing machines" prescribed in
     Article 42 of that law, the machine control system must receive type approval.

2. The F3SG-RA-02TS is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery
     Directive Index Annex V, Item 2.

3. EC/EU Declaration of Conformity
     OMRON declares that the F3SG-RA-02TS is in conformity with the requirements of the following EC/EU Directives:
     Machinery Directive 2006/42/EC
     EMC Directive 2014/30/EU

4. Conforming Standards
     (1) European standards
            EN61496-1 (Type 4 ESPE), EN 61496-2 (Type 4 AOPD), EN61508-1 through -4 (SIL 3),
            EN ISO 13849-1:2015 (PL e, Category 4)
     (2) International standards
            IEC61496-1 (Type 4 ESPE), IEC61496-2 (Type 4 AOPD), IEC61508-1 through -4 (SIL 3),
            ISO 13849-1:2015 (PL e, Category 4)
     (3) JIS standards
            JIS B 9704-1 (Type 4 ESPE), JIS B 9704-2 (Type 4 AOPD)
     (4) North American standards
            UL61496-1 (Type 4 ESPE), UL61496-2 (Type 4 AOPD), UL508, UL1998,
            CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

5. Third-Party Certifications
     (1) TÜV SÜD
            • EC Type-Examination certificate:
                EU Machinery Directive, Type 4 ESPE (EN61496-1), Type 4 AOPD (EN 61496-2)
            • Certificate:
                Type 4 ESPE (EN61496-1), Type 4 AOPD (EN61496-2), EN 61508-1 through -4 (SIL 3),
                EN ISO 13849-1:2015 (PL e, Category 4)
     (2) UL
            • UL Listing:
                Type 4 and ESPE (UL61496-1), Type 4 AOPD (UL61496-2), UL508, UL1998,
                CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

6. Other Standards
      The F3SG-RA-02TS is designed according to the standards listed below. To make sure that the final system complies
      with the following standards and regulations, you are asked to design and use it in accordance with all other related
      standards, laws, and regulations. If you have any questions, consult with specialized organizations such as the body
      responsible for prescribing and/or enforcing machinery safety regulations in the location where the equipment is to
      be used.
       • European Standards: EN415-4, EN691-1, EN692, EN693, IEC 62046
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.212
       • U.S. Occupational Safety and Health Standards: OSHA 29 CFR 1910.217
       • American National Standards: ANSI B11.1 to B11.19
       • American National Standards: ANSI/RIA R15.06
       • Canadian Standards Association CSA Z142, Z432, Z434
       • SEMI Standards SEMI S2
       • Japan Ministry of Health, Labour and Welfare "Guidelines for Comprehensive Safety Standards of Machinery",
         Standard Bureau's Notification No. 0731001 dated July 31, 2007.rms and Conditions Agreement

Indicator

Emitter

Name of Indicator Color Illuminated Blinking
Test TEST Green - External Test is being performed
Operating range LONG Green Always illuminated Lockout state due to Scan code setting error
Power POWER Green Power is ON. Error due to noise
Lockout LOCKOUT Red - Lockout state due to error in emitter

Receiver

Name of Indicator Color Illuminated Blinking
Top-beam-state TOP Blue The top beam is unblocked Lockout state due to Cap error or
Other sensor error
PNP/NPN mode NPN Green Always illuminated -
Configuration CFG Green - Lockout state due to Parameter error
or Cascading Configuration error
External device
monitoring
EDM Green EDM input is in ON state * Lockout state due to EDM error
Internal error INTERNAL Red - Lockout state due to Internal error,
or error due to abnormal power supply or noise
Lockout LOCKOUT Red - Lockout state due to error in receiver
Stable-state STB Green Incident light level is 170% or
higher of ON-threshold
Safety output is instantaneously
turned OFF due to ambient light or vibration
ON/OFF ON/OFF Green Safety output is in ON state -
Red Safety output is in OFF state Lockout state due to Safety Output error,
or error due to abnormal power supply or noise
Communication COM Green Synchronization between emitter
and receiver is maintained
Lockout state due to Communication error,
or error due to abnormal power supply or noise
Bottom-beam
state
BTM Blue The bottom beam is unblocked Lockout state due to Scan code setting error

Note: TOP, CFG, LOCKOUT, STB and ON/OFF indicators are illuminated when the receiver of the F3SG-RA-02TS is in Setting mode.
* The EDM indicator is illuminated when the EDM input is in the ON state regardless of the use of the EDM function.

Interface Unit

Main Unit PC/AT compatible machine (computer that runs Microsoft Windows)
Operating System (OS) Windows 7 (32-bit/64-bit), Windows 8, 8.1 (32-bit/64-bit), Windows 10 (32-bit/64-bit)
Communication Port USB port ×1
Ambient Temperature Operating: -10 to 55°C, Storage: -30 to 70°C (non-icing and non-condensing)
Ambient Humidity Operating: 35% to 85%, Storage: 35% to 95% (non-condensing)

Lamp

Item F39-LP
Applicable Sensor F3SG-[]RA Series Safety Light Curtain (Receiver)
LED Light Color Red/Green/Orange
Power Supply Voltage 24 VDC±20%, ripple p-p 10% max. (shares sensor’s power supply)
Current Consumption 25 mA max. (shares sensor’s power supply.)
Ambient Temperature Operating: -10 to 55°C, Storage: -25 to 70°C
Ambient Humidity Operating: 35% to 85%, Storage: 35% to 95%
Vibration Resistance 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock Resistance 100 m/s2 , 1000 shocks for all 3 axes
Degree of Protection IP65 and IP67 (When attached to F3SG)
Type of Connection Connectable to F3SG-RA’s terminal connector
Material Lighting element: PC, Other body parts: PBT
Weight 45 g (when packaged)