Page top

page-top

DeviceNet Safety System Selection Guide

Model

Appearance

Features

Approved Standard No.

Agency

NE0A Series

Safety Network Controller

NE0A Series Safety Network Controller

Ideal for Safety Applications with Up to 12 Safety Inputs

• Circuits for the required safety category are easy to build.

• The safety circuits you create can be registered as templates and reused, for easy standardization.

• A wide range of TÜV-certified templates is also
available.

• The NE0A operating conditions can be monitored from a standard DeviceNet Master.

• Network distribution is possible by combining with an NE1A Safety Controller.

NFPA 79
ISO13849-1
EN954-1
IEC61508
part1-7/12.98-05.00
IEC61131-2
ISO13849-2
EN61000-6-4
EN61000-6-2
EN60204-1
ANSI RIA15.06
ANSI B11.19
UL508
UL1604
UL1998
NFPA79
IEC61508
CSA22.2 No142
CSA22.2 No213

• TÜV Rheinland

• UL (cUL)

NE1A Series

Safety Network Controller

NE1A Series Safety Network Controller

Achieve Safety Control through Programming

• Compact Safety Controller.

• The NE1A-SCPU01-V1 provides 16 built-in safety
inputs and 8 built-in safety outputs. The NE1A-SCPU02 provides 40 built-in safety inputs and 8 built-in safety outputs.

• Reduced wiring with safety networks. Connect up to 32 Safety Terminals.

• Monitor the safety system from Standard Controllers
across the network.

• EN 954-1/ISO13849-1 CAT4 and IEC 61508 SIL3 certification.

NFPA 79
ISO13849-1
EN954-1
IEC61508
part1-7/12.98-05.00
IEC61131-2
ISO13849-2
EN61000-6-4
EN61000-6-2
EN60204-1
EN418:1992
ANSI RIA15.06
ANSI B11.19
UL508
UL1604
UL1998
NFPA79
IEC61508
CSA22.2 No142
CSA22.2 No213

• TÜV Rheinland

• UL (cUL)

NE1A-SCPU0[]-EIP

Safety Network Controller

NE1A-SCPU0[]-EIP Safety Network Controller

• Monitor the safety system via EtherNet/IP.

• Includes DeviceNet Safety master functionality.

• No external devices are required to connect the Safety Network Controller to EtherNet/IP.

• Contributes to easier maintenance when used in combination with an OMRON EtherNet/IP-compatible PLC.

NFPA 79-2007
ISO13849-1
EN954-1
IEC61508
part1-7/12.98-05.00
IEC61131-2
EN ISO13849-2
EN61000-6-4
EN61000-6-2
EN60204-1
ANSI RIA15.06
ANSI B11.19
UL508
UL1604
UL1998
NFPA79
IEC61508
CSA22.2 No142
CSA22.2 No213

• TÜV Rheinland

• UL (cUL)

NE1A-EDR01

EtherNet/IP-DeviceNet Router

NE1A-EDR01 Series EtherNet/IP-DeviceNet Router

Allows a safety system to be monitored from Ethernet

• The safety system can be remotely operated with a
personal computer.

• The safety system can also be monitored by an
Ethernet-compatible PLC of another brand.

• UDP packet messages supported.

UL508
UL1604
CSA22.2 No142
CSA22.2 No213

• UL (cUL)

DST1-Series

Safety I/O Terminals

DST1-Series Safety I/O Terminals

Distributed Safety Terminals That Reduce Wiring

• Lineup includes four models to accommodate various I/O types and number of I/O points.

• Monitor the safety system from Standard Controllers across the network.

• EN 954-1/ISO13849-1 CAT4. and IEC 61508 SIL3 certification.

• The DST1-XD0808SL-1 also supports logic operation functions for high-speed processing in applications requiring partial stopping of the safety system.

NFPA 79
ISO13849-1
EN954-1
IEC61508
part1-7/12.98-05.00
IEC61131-2
ISO13849-2
IEC62061
EN61000-6-4
EN61000-6-2
EN60204-1
EN418
ANSI RIA15.06
ANSI B11.19
UL508, UL1604
(excluding DST1-MRD08SL-1),
UL1998, NFPA79
IEC61508
CSA22.2 No142
CSA22.2 No213
(excluding DST1-MRD08SL-1)

• TÜV Rheinland

• UL (cUL)

WS02-CFSC1-E

Safety Network Configurator

WS02-CFSC1-E Safety Network Configurator

Programming Software for Creating Safety Circuits

• Performs settings for the Safety Network Controllers and Safety I/O Terminals.

• Provides safety circuit programming functions.

• Provides monitoring functions for safety circuits.

• Includes DeviceNet Configurator functions.

-

-

 

Note:

1. The safety category refers to the highest applicable category that can be selected when a safety block is created for a control system. It is not the safety category applicable to the safety component itself.

 

2. Production of the NE1A-SCPU01 has been discontinued at the end of April 2009. The recommended substitute will be the NE1A-SCPU01-V1.