G9SP
Safety Controller |
|
Handles complex safety control
applications with easy programming.
Create function blocks with applicable Support Software. Also
performs simulations.
Restore design assets with Memory Cards without using a
computer.
|
EN
ISO13849-1:2008
EN ISO13849-2:2008
IEC61508 parts 1-7:2010
IEC/EN62061:2005
IEC 61131-2:2007
EN ISO13850:2008
(EN418:1992)
EN 60204-1:2006
EN 61000-6-2:2005
EN 61000-6-4:2007
NFPA 79-2007
ANSI RIA 15.06-1999
ANSI B11.19-2003
UL1998
UL508
CSA22.2 No. 142 |
TάV Rheinland
UL (cUL)
|
|
G9SP Configurator |
|
This programming software creates
safety circuits for the G9SP.
Easy system configuration and I/O setup.
Easy system verification with
simulations.
Create software objects to greatly
reduce design work.
|
--- |
---
|
|
G9SX
Flexible Safety Unit |
|
Logical AND connection enables partial or full control.
Uses solid-state output (excluding Expansion Units).
LED indicators provide details of failure diagnosis.
|
EN50178
ISO13849-1
EN954-1
IEC/EN60204-1
IEC/EN61508
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
CAN/CSA C22.2
No.142 |
TάV SάD
UL
KOSHA
|
|
G9SX-GS
Safety Guard
Switching Unit |
|
Auto Switching and Manual Switching functions support two types
of application.
External indicator outputs enable indicating the switching
status of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in
combination with other G9SX-series Units.
|
EN50178
IEC/EN60204-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
IEC61508
CAN/CSA C22.2
No.142 |
TάV SάD
UL (cUL)
KOSHA
|
|
G9SX-SM
Standstill Monitoring Unit |
|
The back electromotive force (BEMF) signal is used to determine
when the motor has stopped.
A standard configuration for standstill detection enables
immediate application without setup.
User configuration to adjust settings for individual machines is
also possible.
Detailed indicator displays for fault diagnosis.
Certified for Safety Category 4 (EN 954-1), PLe (ISO 13849-1),
and SIL3 (IEC/EN 62061).
|
EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142 |
TάV SάD
UL (cUL)
|
|
G9SX-LM
Low-speed Monitoring
Unit |
|
Detects the motor speed with a proximity sensor.
Monitors to see if the motor is below the speed level that has
been set for the specific hazard source.
Enable switch input provided for maintenance work.
Detailed indicator displays for fault diagnosis.
Certified for Safety Category 3 (EN 954-1), PLd (ISO 13849-1),
and SIL3 (IEC/EN 62061).
|
EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142 |
TάV SάD
UL (cUL)
|
|
G9SA
Safety Relay Unit |
|
Compact design.
Two-hand Controller model available.
Simple connection of Expansion Unit.
High-speed 10-ms response.
Incorporates LED indicators for monitoring built-in relays.
Finger protection construction.
3-pole, 5-pole and Off-delay Units available.
|
EN60204-1 ISO13849-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
BG
UL
CSA
CQC
|
|
G9SB
Safety Relay Unit |
|
Ultra-compact, with models starting at only 17.5 mm wide.
Can be used with Safety Sensors.
High-speed 10-ms response.
Incorporates LED indicators for monitoring built-in relays.
Finger protection construction.
|
EN60204-1 ISO13849-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
TάV Rheinland
UL
CSA
CQC
|
|
G9S
Safety Relay Unit |
|
Two-pole, three-pole, five-pole, and OFF-delay models are
available.
Incorporates LED indicators for monitoring built-in relays.
Finger-protection construction.
|
EN60204-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
BIA
UL
CSA
CQC
|
|
F3SP-B1P
Control Unit for
Safety Sensor |
|
Control Unit for F3SN-A, F3SN-B, F3SH-A, F3SR-B and F3SJ-B.
Plug in light curtain connectors on both sides.
|
TάV SάD and UL certified in a set with F3SN-A, F3SN-B, and F3SH-A.
|