Page top

page-top

Omron uses cookies to improve your experience on this website. By continuing to use the website, you hereby agree to our Privacy and Cookie Policy

Primary Contents

Safety Door Switches

Model Ratings Standard No. File No.
D4BS A600(Carry current: 10A) CSA C22.2
No.14
LR45746
D4BL Model without Indicator: A300 (Carry current: 10A)
Model with Indicator: 6A, 115V AC
LR45746
D4GL C300(Carry current: 2.5A), Q300(Carry current: 2.5A) (C-UL listing based on Canadian safety standards)
Refer to UL Certification
D4NL A300(Carry current: 10A), Q300(Carry current: 2.5A)
D4JL
D4NS
D4NH
D4GS-N C300(Carry current: 2.5A), Q300(Carry current: 2.5A)
D4SL-N C150(Carry current: 2.5A), R150(Carry current: 1A) (C-UL recognition approval for Canadian safety standards)
Refer to UL Certification

Compact Non-contact Door Switches

Model Standard No. File No.
D40A * CSA C22.2 No.14 (C-UL listing based on Canadian safety standards)
Refer to UL Certification
D40Z * (C-UL listing based on Canadian safety standards)
Refer to UL Certification
* Note: Use the product in combination with the G9SX-NS/NSA.

Safety Limit Switches

Model Ratings Standard No. File No.
D4B-N A600(Carry current: 10A) CSA C22.2
No.14
LR45746
D4F C300(Carry current: 2.5A), Q300(Carry current: 2.5A) (C-UL listing based on Canadian safety standards)
Refer to UL Certification
D4N A300(Carry current: 10A), Q300(Carry current: 2.5A)
D4N-[]R

Safety Sensors

Model Ratings/Remarks Standard No. File No.
F3SR-B Input:
24V DC

Output:
PNP transistor output
500mA(24V DC)

TYPE 4 ESPE/AOPD
CSA C22.2 No.0.8
CSA C22.2 No.14
(C-UL listing based on Canadian safety standards)
Refer to UL Certification
F3SJ-A Input:
24V DC

Output:
PNP or NPN transistor output
300mA(24V DC)

TYPE 4 ESPE/AOPD
CSA C22.2 No.0.8
CSA C22.2 No.14
F3SJ-E
F3SJ-B
Input:
24V DC

Output:
PNP or NPN transistor output
200mA(24V DC)

TYPE 4 ESPE/AOPD
CSA C22.2 No.0.8
CSA C22.2 No.14
MS4800 Input:
24V DC

Output:
PNP transistor output
625mA(24V DC)

TYPE 4 ESPE/AOPD
CSA C22.2 No.205 1289466
E3FS * TYPE 2 ESPE/AOPD CSA C22.2 No.0.8
CSA C22.2 No.14
(C-UL listing based on Canadian safety standards)
Refer to UL Certification
E3ZS * CSA C22.2 No.0.8
CSA C22.2 No.14
F3SP-T01 Input:
24V DC
Contact output:
3A 250V AC(Resistive)
3A 30V DC(Resistive)
CSA C22.2 No.14
F3SP-B1P Input:
24V DC
Contact output:
5A 250V AC(Resistive)
5A 30V DC(Resistive)
CSA C22.2 No.0.8
CSA C22.2 No.14
* Note: Use the product in combination with the F3SX.

Safety Laser Scanner

Model Ratings/Remarks Standard No. File No.
OS32C TYPE 3 ESPE/AOPDDR CSA C22.2 No.0.8
CSA C22.2 No.14
(C-UL listing based on Canadian safety standards)
Refer to UL Certification

Emergency Stop Switches

Model Ratings Standard No. File No. Remarks
A165E 5A 125V AC(General Use)
3A 250V AC(General Use)
3A 30V DC(Resistive)
CSA C22.2
No.14
(Recognition approval for Canadian safety standards )
Refer to UL Certification
Separate construction models have been certified for the Switch Unit.
A165E-[]-03U 1A 125V AC(General Use)
0.5A 250V AC(General Use)
1A 30V DC(Resistive)
――
A22E 6A 220V AC(General Use)
10A 110V AC(General Use)
(Recognition approval for Canadian safety standards )
Refer to UL Certification
Certified for the Switch Block and Lamp Socket.

Safety Swich

Model Ratings Standard No. File No.
A4E 1A 125V AC (Resistive)
300mA 24V DC (Pilot Duty)
CSA C22.2
No.14
(Recognition approval for Canadian safety standards )
Refer to UL Certification
A4EG (Enabling Switch)
1A 125V AC (Resistive)
300mA 24V DC (Pilot Duty)
(Emergency Stop Switch)
5A 125V AC (General Use)
3A 250V AC (General Use)
3A 30V DC (Resistive)
(Pushbutton Switch)
0.1A 125V AC (Resistive)
0.1A 30V DC (Resistive)
(C-UL listing based on Canadian safety standards)
Refer to UL Certification

Safety Mat Controllers

Model Ratings/Remarks Standard No. File No.
MC3 Input:
24V DC
Contact output:
6A, 250V AC
6A, 24V DC max.
CSA C22.2 No.0.8
CSA C22.2 No.14
1165614

DeviceNet Safety System

Model Standard No. File No.
NE0A CSA C22.2 No.142
CSA C22.2 No.213[Except for DST1-MRD08SL-1]
(C-UL listing based on Canadian safety standards)
Refer to UL Certification
NE1A
DST1

Relays with Forcibly Guided Contacts

Model Number of Poles Operating Coil Contact Ratings Standard No. File No.
G7SA-3A1B 3PST-NO/SPST-NC 24V DC 6A 250V AC(Resistive)
6A 30V DC(Resistive)
CSA C22.2 No.14 LR35535
G7SA-2A2B DPST-NO/DPST-NC
G7SA-5A1B 5PST-NO/SPST-NC
G7SA-4A2B 4PST-NO/DPST-NC
G7SA-3A3B 3PST-NO/3PST-NC
G7S-4A2B-E 4PST-NO/DPST-NC 24V DC NO contact:
10A per pole, 20A total,
277V AC(Resistive)

NC contact:
6A per pole, 20A total,
277V AC(Resistive)
CSA C22.2 No.14 LR35535
G7S-3A3B-E 3PST-NO/3PST-NC

Safety Relay Units

Model Standard No. File No.
G9SA-301 CSA C22.2 No.14 LR51460
G9SA-501
G9SA-321-T[]
G9SA-TH301
G9SA-EX301
G9SA-EX031-T[]
G9SA-300-SC
G9SB-200[]-[]
G9SB-301[]-[]
G9SB-3010

Flexible Safety Unit

Model Standard No. File No.
G9SX-AD
G9SX-ADA
G9SX-BC
G9SX-EX
G9SX-GS
G9SX-NS
G9SX-NSA
G9SX-LM
G9SX-SM
CSA C22.2 No.142 (C-UL listing based on Canadian safety standards)
Refer to UL Certification

Safety Controller

Model Standard No. File No.
G9SP CSA C22.2 No.142 (C-UL listing based on Canadian safety standards)
Refer to UL Certification