Page top

page-top

Omron uses cookies to improve your experience on this website. By continuing to use the website, you hereby agree to our Privacy and Cookie Policy

Primary Contents

Power Supplies

Model Ratings Standard No. File No. Marking Listed/Recognized Category
S82S 12 to 24V DC UL508 E104818 RU Recognized NMTR2
S8AS 100 to 240V AC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8EA-N/BN
(50/75/100/150W)
100 to 120V AC UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8EX-N
(15/30W)
100 to 240V AC UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8EX-P/BP
(50/100/150W)
100 to 240V AC UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8EX-BP
(240W)
100 to 240V AC UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8JX-G
(15/30/50/100/150(except 5V)W)
100 to 240V AC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8JX-G
(150(5V)/300/600W)
100 to 120V / 200 to 240V AC UL508 E316988 cRUus Recognized NMTR2/NMTR8
UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8M 24V DC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8T-DCBU-01 24V DC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8T-DCBU-02 24V DC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8TS
(25/30/60W)
100 to 240V AC UL508 E316988 cULus Listed NMTR/NMTR7
UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8VM
(15/30/50/100/150/300(24V)/600W(24V))
100 to 240V AC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognize QQGQ2/QQGQ8
S8VM
(300(5/12/15V)/600(5/12/15V)/1500W)
100 to 240V AC UL508 E104818 cRUus Recognized NMTR2/NMTR8
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8VS
(15/30/90/120/240W)
100 to 240V AC UL508 E316988 cULus Listed NMTR/NMTR7
UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
S8VS
(480W)
Screw terminal block
100 to 240V AC UL508 E104818 cULus Listed NMTR/NMTR7
UL60950-1 E152784 cRUus Recognized QQGQ2/QQGQ8
S8VS
(480W)
Screwless terminal block
100 to 240V AC UL508 E316988 cULus Listed NMTR/NMTR7
UL60950-1 E319923 cRUus Recognized QQGQ2/QQGQ8
Supplying Power to Sensors with DC Power Supplies
If a class-2 power supply is used, the Sensor itself does not have to be UL compliant; a standard model may be used.
The following Power Supplies comply with class 2.
Model File No. Remarks
S8AS E104818
S8TS(25/30/60W) E316988 Single-unit operation
S8VS(15/30/60/90(only models ending in "-S")W)
S8M(-CP04-RS) E104818
S8T-DCBU-01 *
S8T-DCBU-02 *
*Refer to the ratings, characteristics, and functions of the S8T-DCBU-01 and S8T-DCBU-02 for details.

Axial-flow Fans

Model Ratings Standard No. File No.
R87F-A[]A15HP
R87F-A[]A15MP
R87F-A[]A15LP
[]=1
[]=3
[]=4
[]=6
100V AC 50/60Hz
115V AC 50/60Hz
200V AC 50/60Hz
230V AC 50/60Hz
UL507 E100651
R87F-A[]A13HP
R87F-A[]A13LP
R87F-A[]A93HP
R87F-A[]A93LP
R87F-A[]A85HP
R87F-A[]A85LP
R87F-A[]A83H
R87F-A[]A83L
R87T-A[]A15HP
R87T-A[]A15MP
R87T-A[]A07H
R87T-A[]A05H
R87T-A[]A85H
R87T-A[]A83H
R87F-A[]A15H-WR

Power/Component Protective Components

Model Ratings File No.
SDV-F[][] 24V DC, 48V DC,
100/110V DC, 125V DC,
100/110V AC, 200/220V AC
E41515
K8AB-AS/-VS/-VW 24V AC/DC,
100/115V AC, 200/230V AC
E76675
K8AB-PH 200 to 500V AC(three-phase three-wire system)
K8AB-PM/-PA/-PW 200 to 480V AC(three-phase three-wire system)
K8AC-H 100 to 240V AC E200593
K8AK-LS 24V AC/DC,100 to 240V AC E329670
K8AK-AS/-AW/-VS/-VW 24V AC/DC,100 to 240V AC
K8AK-PH 200 to 480V AC(3-phase 3-wire)
K8AK-PM/-PA/-PW 1 : Low (3-phase 3-wire : 200/220/230/240V,
3-phase 4-wire : 115/127/133/138V)
2 : High (3-phase 3-wire : 380/400/415/480V,
3-phase 4-wire : 220/230/240/277V)
K8DS-PH 200 to 480V AC(3-phase 3-wire)

Wiring-reduction and Work-saving Components: Industrial Ethernet Connectors

Model Standard No. File No.
XS5 * UL2238 E207683
XS6 * UL1977 E103202
* The above table lists series names. Ask your OMRON representative for details on specific model numbers.

Wiring-reduction and Work-saving Components: Sensor I/O Connectors

Model Standard No. File No.
XS5 * UL2238 E207683
XS2 * UL2238 E207683
XN2 UL1977 E103202
* The above table lists series names. Ask your OMRON representative for details on specific model numbers.

Wiring-reduction and Work-saving Components: Connector-Terminal Block Conversion Units

Model Standard No. Standard No. Marking Listed/Recognized Category
XW2B (Servo Relay Units) UL508
ANSI/ISA12.12.01
E198998 cULus Listed NRAG/NRAG7
XW2B (Standard-type) UL508 E95399 cULus * Listed NRAQ/NRAQ7
XW2Z
* Marking not all show on certification products.
Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Products that are certified for ANSI/ISA12.12.01 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.
Description of Hazardous Locations:
[Class]
Class I: Locations in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable.
Class II: Locations in which there is combustible dust.
Class III: Locations in which easily ignitable fibers or flyings are present
but are not airborne in sufficient quantities to ignite.
[Division]
Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
【Group】
Class I :
Group A: Acetylene
Group B: Combustible gas/vapor, example: hydrogen
Group C: Combustible gas/vapor, example: ethylene
Group D: Combustible gas/vapor, example: propane

Sensor Controllers

Model File No.
(Category Control Number)
Ratings/Remarks
S3D2-AKB-US, -AK-US
S3D2-CKB-US, -CK-US
S3D2-BK-US
E41515
(Recognition approval)
NRNT2、NRNT8
Inputs:
100 to 240V AC 50/60Hz

Outputs:
3A 250V AC(Resistive)
S3D2-CCB-US, -CC-US Inputs:
100 to 240V AC 50/60Hz

Outputs:
100mA 30V DC
Sensors with DC Power-supply Specifications of 30 V Max.
1.
Use an OMRON S8VS Power Supply or other Class-2, UL-certified power supply for Sensors with power supply specifications of 30 V max.
Class-2 power supplies have output limiting capability that meets the requirements of UL 1310 or UL 1585.
With a Class-2 power supply, it is extremely unlikely that a fire will occur because of the lower amount of energy that is supplied.
2.
Sensors with power supply specifications of 30 V max. can be used in the US without UL certification if they are used with a UL-certified Class-2 power supply.
3.
Certification has been obtained for the models given in the following table, subject to the condition of use for Class-2 circuits.
Model File No.
E3 ( ) Series E41515
(Recognition approval)
E2 ( ) Series
TL ( ) Series
E4 ( ) Series
E6 ( ) Series
E8 ( ) Series
F3M Series
EE-S Series
Note: Numbers or letters are inserted in the parentheses that appear in the "Model" column.

Common Sockets

Model Ratings File No.
PF083A(-E)
PF113A(-E)
10A 250V E87929
8PFA
8PFA1
11PFA
14PFA
7.5A 250V
PY[]
PY[]A(-E)
7A 250V
PYF08S
PYF14S
10A 250V AC
PT08
PTF08A(-E)
15A 250V
PT11
PT14
PTF11A
PTF14A(-E)
10A 250V
P2CF-08(-E)
P2CF-11(-E)
10A, 250V AC
P3G-08 6A, 250V AC
P3GA-11 6A, 250V AC
PL08
PL11
PLE08-0
PLE11-0
10A 260V
P6B-06 8A 250V AC
P6B-26P 5A 250V AC
P6C 10A 250V AC
P2R(F)-05(-E) 10A 300V AC
P2R(F)-08(-E) 5A 300V AC
P2RF-05-S 10A 250V AC
P2RF-08-S 5A 250V AC
P6D ――
P7TM-06P 15A 250V
P7TM-06(-D) 15A 250V
P7TF-05 10A 250V
 
 
Model Contact Ratings
P7S-[] ―――
P7SA-[]