D6FZ-FGT Series

Air Flow Sensor

D6FZ-FGT Series

The best Product to Measure Compressed Air at Machine. Measurement of Leakage and Usage.

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Ratings

Air Flow Sensor

Model D6FZ-FGT200 D6FZ-FGT500
Applicable fluid Air or nitrogen (N2) *1
Working pressure 0.75MPa (withstand pressure 1.5MPa)
Measurement range*2 0 to 200L/min 0 to 500L/min
Measurement accuracy
range*2
2 to 200L/min 5 to 500L/min
Display Resolution*2 1L/min
Accuracy*2 ±2.0%F.S. at 50L/min or more
±0.5%F.S. at less than 50L/min
Temperature characteristic ±3%F.S.
Repeat accuracy ±1%F.S.
Operating temperature Operation: -10 to 60°C / Storage: -20 to 70°C (no condensation or icing)
Operating humidity Operation: 25 to 90%RH / Storage: 0 to 90%RH (no condensation or icing)
Shock resistance 150 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each
Pressure loss 2kPa max. 4kPa max.
Power supply voltage 12 to 24 VDC ±10% ripple (p-p) 10% max.
Current consumption 120mA max.
Functions Momentary flow / Integrated flow / Reversing display / Zero point Adjustment /
Peak and Bottom Hold / Key Lock / Eco Mode / Scaling (Analog Output) /
Judgement Hysteresis / Teaching
Display 11-segment digital display (Red), RUN / FUN / THR (Yellow),
Out1 / Out2 (Yellow), Key Lock (Yellow),
Flow unit (Green), Flow unit in reversed display (Yellow)
Output Output
interface
Analog Current output 4 to 20mA (1 contact), maximum load resistance 300Ω max.
ON/OFF Open collector output (2 outputs) 26.4 VDC 50mA max.
ON residual voltage 2V max.
(Outputs can be selected from judgement output, pulse output and unit error output)
RS-485 2-wire half duplex communication, start-stop synch method
Baud rate: 9.6k/19.2k/38.4k/115.2kbps, data bit length: 7/8bit,
stop bit length: 1/2bit, parity: none/even/odd,
termination resister (120Ω): ON/OFF,
communications protocol: compatible with CompoWay/F
Output values Momentary flow, Integrated flow, Judgement output *3, Unit error output
Degree of protection IP65
Installation Direction and
Straight Pipe Section
A straight pipe section must be provided during installation and piping if the Sensor is
installed horizontally and the display is on the top. *4
Connection bore diameter Rc1/4 (8A) Rc1/2 (15A)
Material Main unit: PBT / Flow channel: Zinc
Dimensions 30(W) × 77(D) × 63.7(H) mm
Weight (in package) Approx. 400 g (500 g)
Accessories Instruction Sheet

*1. Clean Dry Gas (must not contain large particle e.g. duct, oil and mist)
*2. Converted value assuming the accumulated flow quantity following conditions
      std (factory default) : 20°C at 1 atmospheric pressure 101.3kPa, nor : 0°C at 1 atmospheric pressure 101.3kPa
*3. To prevent chattering, a judgement output is made when the judgement continues for one minute or longer.
*4. The accuracy will depend on the length of the straight pipe section. Refer to Flow rate accuracy characteristics for a
      length of straight pipe on Catalog for details.

Air Flow Station

Model D6FZ-FGX21
Connectable sensor D6FZ-FGT200 / D6FZ-FGT500 / D6FZ-FGS1000
Maximum number of
mounted Sensors
8 units*1
Display 7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays
Recording interval 1 s, 2 s, 5 s, 10 s, 20 s, 30 s, 1 min.
Displayed data Momentary flow rate, integrated flow rate, pressure, temperature, charge/CO2
conversion value
Recorded data Momentary flow rate, integrated flow rate, volume flow rate, pressure, temperature
Operation function Conversion of integrated flow rate to charge/CO2
Recording mode Continue mode*2, Ring mode*3
External output Alarm output (Photocoupler output) *4
Communication interface Ethernet (10BASE-T, 100BASE-TX)
Internal storage device Internal memory: Approx. 4200 data items when 1 unit is connected,
approx. 650 data items when 8 units are connected
External storage device SD card (measured value saving/set value saving and reading), Recommended SD card:
HMC-SD291 (2 GB) *9 and HMC-SD491 (4 GB) (manufactured by OMRON) *5
Power supply voltage DC input: 24 VDC±10% ripple (p-p) 10% max.
Current consumption 80 mA max.
Operating temperature Without Ethernet: -10°C to 40°C (no condensation or icing),
with Ethernet: 0°C to 40°C (no condensation or icing)
Operating humidity 35 to 85%RH (no condensation or icing)
Storage humidity/
temperature
-15°C to 60°C, 20% to 85%RH (no condensation or icing)
Insulation resistance 20 MΩ (500 VDC)
Withstand voltage 1000 VAC, 50/60 Hz, 1 min.
Vibration resistance 10 to 150 Hz, 0.7 mm double amplitude,
acceleration: 50 m/s2 for each in X, Y and Z directions for 80 min
Shock resistance 150 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each*6
Material ABS
Degree of protection IP30
Mounting Magnet mounting, screw mounting, hook
Dimensions 117.2(W) × 24.6(D) × 56.8(H) mm (Except protruding part)
Weight (in package) Approx. 150 g (Approx. 500 g)
Accessories Instruction Sheet, Startup Guide, T-branch connection cable*7, Alarm Output Connector*8

*1. Up to 8 units can be connected when the recording cycle is 2 seconds or longer; up to 4 units when the recording cycle is
      1 second.
*2. Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues
      recording until the SD card memory capacity reaches its limit.
      The unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity, or when
      it is write protected. (Recording can be resumed after inserting an SD memory card and outputting the data to it at a
      press of button.)
      The factory default is continue mode. Use the PC software to change the recording mode.
*3. Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal
      memory capacity exceeds the capacity, data is overwritten from the oldest one in the memory.)
*4. Output when the range of upper/lower limit of the air flow that has been set in threshold setting mode is exceeded.
*5. When using a third party SD card, it is recommended to use a reliable and durable industrial SD card (SD standard or
      SDHC standard (not compliant with SDXC standard), Class 4 or higher, flash memory type SLC or MLC type).
      You must confirm the operation of the SD card yourself.
*6. When using a mounting magnet, be sure to install it in a location where shock is not applied.
*7. A T-branch connector to connect to D6FZ-FC02.
*8. OMRON's XW4B-02B1-H1 connector
*9. Orders for HMC-SD291 will be accepted until the end of March 2022.