RFID System
last update: April 1, 2015
Model | V680S-HMD63-EIP
V680S-HMD63-PNT |
V680S-HMD64-EIP
V680S-HMD64-PNT |
V680S-HMD66-EIP
V680S-HMD66-PNT |
---|---|---|---|
Dimensions | 50W × 50H × 30D
(excluding protruding parts and cables) |
75W × 75H × 40D
(excluding protruding parts and cables) |
120W × 120H × 40D
(excluding protruding parts and cables) |
Power supply voltage | 24 VDC (-15% to +10%) | ||
Consumption current | 0.2A max. | ||
Ambient operating temperature | -10 to +55 °C (with no icing) | ||
Ambient operating humidity | 25% to 85% (with no condensation) | ||
Ambient storage temperature | -25 to 70 °C (with no icing) | ||
Ambient storage humidity | 25% to 85% (with no condensation) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) between cable terminals and case | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case | ||
Vibration resistance | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude,
acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in 6 directions (Total: 18 times) | ||
Degree of protection | IP67 (IEC 60529: 2001)
Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1) * |
||
Materials | Case: PBT resin, Filled resin: Urethane resin | ||
Mass | Approx. 240g | Approx. 390g | Approx. 760g |
Installation method | Reader/Writer: Two M4 screws
(Use a screw of 12 mm or more in length.) Branch cable joint: One M4 screws |
Four M4 screws
(Use a screw of 12 mm or more in length.) |
|
Host device communications
interface |
Ethernet 10BASE-T/100BASE-TX | ||
Host device communications
protocol |
EtherNet/IP, PROFINET | ||
Accessories | Instruction Sheet, Description of Regulations and Standard, IP address label |
* Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: The 0.5 m cable with two M12 connectors is attached to the Reader/Writer. The cable cannot be removed.
Model | V680S-HMD63-ETN | V680S-HMD64-ETN | V680S-HMD66-ETN |
---|---|---|---|
Dimensions | 50W × 50H × 30D
(excluding protruding parts) |
75W × 75H × 40D
(excluding protruding parts) |
120W × 120H × 40D
(excluding protruding parts) |
Power supply voltage | 24 VDC ( - 15% to + 10%) | ||
Consumption current | 0.2A max. | ||
Ambient operating temperature | - 10 to + 55 °C (with no icing) | ||
Ambient operating humidity | 25% to 85% (with no condensation) | ||
Ambient storage temperature | - 25 to 70 °C (with no icing) | ||
Ambient storage humidity | 25% to 85% (with no condensation) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) between cable terminals and case | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case | ||
Vibration resistance | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude,
acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in 6 directions (Total: 18 times) | ||
Degree of protection | IP67 (IEC 60529: 2001)
Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1) *1 |
||
Materials | Case: PBT resin, Filled resin: Urethane resin | ||
Mass | Approx. 120g | Approx. 270g | Approx. 640g |
Installation method | Two M4 screws
(Use a screw of 12 mm or more in length.) |
Four M4 screws
(Use a screw of 12 mm or more in length.) |
|
Host device communications
interface |
Ethernet 10BASE-T/100BASE-TX | ||
Host device communications
protocol |
MODBUS TCP | ||
Accessories | Instruction sheet, Description of Regulations and Standard, IP address label, Ferrite core *2 |
*1 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
*2 Provided only with the V680S-HMD66-ETN.
Model | V680S-D2KF67 | V680S-D2KF67M | V680S-D2KF68 | V680S-D2KF68M |
---|---|---|---|---|
Memory capacity | 2,000 bytes (user area) | |||
Memory type | FRAM | |||
Data Retention | 10 years after writing (85 °C or less) | |||
Memory life | One trillion writes for each block (85 °C or less), Access frequency *1: One trillion accesses | |||
Ambient operating
temperature |
-20 to 85 °C (with no icing) | |||
Ambient storage
temperature |
-40 to 125 °C (with no icing) | |||
Ambient operating
humidity |
35% to 85% | |||
Degree of protection | IP68 (IEC 60529:2001),
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *2. IPX9K (DIN 40 050) |
|||
Vibration resistance | No abnormality after application of
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
No abnormality after application of
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps each in X, Y, and Z directions for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2,
3 times each in X, Y, and Z directions (Total: 18 times) |
|||
Dimensions | 40 × 40 × 5 mm (W × H × D) | 86 × 54 × 10 mm (W × H × D) | ||
Materials | PPS resin | |||
Weight | Approx. 11.5 g | Approx. 12 g | Approx. 44 g | Approx. 46 g |
Metal countermeasures | None | Provided | None | Provided |
*1 The number of accesses is the total number of reads and writes.
*2 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Model | V680S-D8KF67 | V680S-D8KF67M | V680S-D8KF68 | V680S-D8KF68M |
---|---|---|---|---|
Memory capacity | 8,192 bytes (user area) | |||
Memory type | FRAM | |||
Data Retention | 10 years after writing (85 °C or less) | |||
Memory life | One trillion writes for each block (85 °C or less), Access frequency *1: One trillion accesses | |||
Ambient operating
temperature |
-20 to 85 °C (with no icing) | |||
Ambient storage
temperature |
-40 to 125 °C (with no icing) | |||
Ambient operating
humidity |
35% to 85% | |||
Degree of protection | IP68 (IEC 60529:2001),
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *2. IPX9K (DIN 40 050) |
|||
Vibration resistance | No abnormality after application of
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
No abnormality after application of
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps each in X, Y, and Z directions for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2,
3 times each in X, Y, and Z directions (Total: 18 times) |
|||
Dimensions | 40 × 40 × 5 mm (W × H × D) | 86 × 54 × 10 mm (W × H × D) | ||
Materials | PPS resin | |||
Weight | Approx. 11.5 g | Approx. 12 g | Approx. 44 g | Approx. 46 g |
Metal countermeasures | None | Provided | None | Provided |
*1 The number of accesses is the total number of reads and writes.
*2 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Model | V680-D1KP54T | V680-D1KP66T | V680-D1KP66MT | V680-D1KP66T-SP |
---|---|---|---|---|
Memory capacity | 1,000 bytes (user area) | |||
Memory type | EEPROM | |||
Data retention time | 10 years after writing (85 °C or less),
0.5 year after writing (85 °C to 125 °C) Total data retention at high temperatures exceeding 125 °C is 10 hours *1 |
10 years after writing
(85 °C or less) |
||
Write endurance | 100,000 writes for each block (25 °C) | |||
Ambient operating
temperature (during transmission) |
- 25 to 85 °C (with no icing) | During RF Tag
communications: -25 to 70 °C (with no icing) Not during RF Tag communications: -40 to 110 °C (with no icing) |
||
Ambient storage
temperature (during data backup) |
- 40 to 125 °C (with no icing)
Heat resistance: 1,000 thermal cycles each of 30 minutes at - 10 °C/150 °C, High temperature storage: 1,000 hours at 150 °C *2 200 thermal cycles each of 30 minutes at - 10 °C/180 °C, High temperature storage: 200 hours at 180 °C *3 |
- 40 to 110 °C
(with no icing) |
||
Ambient operating
humidity |
35 to 95% | |||
Degree of protection | IP67 (IEC 60529:2001)
Oil resistance equivalent to IP67G (JIS C 0920: 2003, Appendix 1) *4 |
IP68 (IEC 60529:2001)
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *4 |
IP67 | |
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude,
acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
|||
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in X, Y, and Z directions (Total:
18 times) |
|||
Appearance | 20 dia. × 2.7 mm | 34 × 34 × 3.5 mm | 95 × 36.5 × 6.5 mm
(excluding protruding parts) |
|
Materials | PPS resin | Exterior: PFA fluororesin
RF Tag filling: PPS resin |
||
Weight | Approx. 2 g | Approx. 6 g | Approx. 7.5 g | Approx. 20 g |
Metal
countermeasures |
None | None | Provided | None |
*1 After storing data at high temperatures, rewrite the data even if changes are not required. High temperatures are those exceeding 125 °C up to 180 °C.
*2 150 °C heat resistance: The heat resistance has been checked at 150 °C for up to 1,000 hours, and thermal shock has been checked through testing 1,000 thermal cycles each of 30 minutes at −10/150 °C. (Test samples: 22, defects: 0)
*3 180 °C heat resistance: The heat resistance has been checked at 180 °C for up to 200 hours, and thermal shock has been checked through testing 200 thermal cycles each of 30 minutes at −10 °C/180 °C. (Test samples: 22, defects: 0)
*4 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User's Manual (Cat. No. Z339).
Model | V680-D1KP58HTN |
---|---|
Memory capacity | 1,000 bytes (user area) |
Memory type | EEPROM |
Data Retention | 10 years after writing (85 °C or less), 0.5 year after writing (85 °C to 125 °C)
Total data retention at high temperatures exceeding 125 °C is 10 hours *1 |
Write Endurance | 100,000 writes for each block (25 °C) |
Ambient operating temperature
(during transmission) |
- 25 to 85 °C (with no icing) |
Ambient storage temperature
(during data backup) |
-40 to 250 °C (with no icing) *2
(Data retention: -40 to 125 °C) 1. 2,000 cycles of 30 minutes each between room temperature and 200 °C 2. 500 hours at 250 °C |
Ambient storage humidity | No restrictions. |
Degree of protection | IP67 (IEC 60529:2001)
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *3 |
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude,
acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in X, Y, and Z directions
(Total: 18 times) |
Materials | PPS resin |
Weight | Approx. 70 g |
*1 After storing data at high temperatures, rewrite the data even if changes are not required. High temperatures are those exceeding 125 °C up to 250 °C.
*2 Storing RF Tags under high temperatures or under heat cycles will adversely affect the performance of the internal parts and the service life of the RF Tags. The RF Tag were placed in the following high temperatures and then evaluated in-house. It was confirmed that no problems occurred.
1. 2,000 cycles of 30 minutes each between room temperature and 200 °C.
2. 500 hours at 250 °C.
*3 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User's Manual (Cat. No. Z339, Z353 or Z354).
last update: April 1, 2015