NL

Limit Touch Switch

NL

Object Actuates Switch and Turns Built-in Monitor Indicator ON

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Model NL1 NL2 NL3
Degree of protection IP60
Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC
Rated frequency --- 50/60 Hz
Sensitivity Grounded object: Contact resistance of 3 kΩ max.
Non-grounded object: Antenna-to-ground capacitance of 100 pF min.
Current consumption 8 mA 15 mA ---
Leakage current --- Circuit: 2 mA; Antenna: 1 mA *1
Response time 5 ms max. 20 ms max.
Output signal Voltage output model: 30
mA at 12 VDC with output
impedance of 4.7 kΩ
Current output model:
24 VDC (directly
switching resistive load
of 170 mA max.)
Thyristor output model: 100 or 200
VAC (directly switching resistive load
of 30 to 300 mA) *2
Insulation resistance 0 V (blue lead wire) is connected to casing 100 MΩ min. at 500 VDC *3
Dielectric strength 0 V (blue lead wire) is connected to casing 1,500 VAC at 50/60 Hz for 1 min *3
Pollution degree
(operating environment)
3 (IEC947-5-1)
Protection against
electric shock
Class II
Proof tracking index
(PTI)
175
Switch category D (IEC335)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance 200 m/s2 max.
Ambient temperature -10°C to +60°C (with no icing)
Ambient humidity 35% to 95%RH
Weight Approx. 370 g (NL[]-C, -P) Approx. 550 g (NL[]-S) Approx. 680 g (NL[]-SP, -SC)

*1. The NL3 has a capacitor and resistor for the protection of the built-in SCR. Therefore, the NL3 has leakage current.
*2. The NL3 requires a current of 30 mA for circuit protection.
        If the load current is less than 30 mA, connect the bleeder resistance R in parallel with the load as shown below so
        that the total current of the load circuit will be 30 to 300 mA.
        Obtain R from the following formula.

NL Specifications 2

Make sure that the permissible power of the resistor is sufficient.

NL Specifications 3

*3. Between current-carrying and non-current-carrying metal parts