Total Counter/Time Counter (DIN 72 x 36)
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: July 20, 2016
Item | 6-digit total counter/time counter | 8-digit total counter | |||
---|---|---|---|---|---|
H7HP-A | H7HP-AD | H7HP-C8 | H7HP-C8D | ||
Rated supply voltage | 100 to 240 VAC
(50/60 Hz) |
12 to 24 VDC *1 | 100 to 240 VAC
(50/60 Hz) |
12 to 24 VDC *1 | |
External power supply | 50 mA at 12 VDC | --- | 50 mA at 12 VDC | --- | |
Operating voltage range | 85% to 110% of rated supply voltage | ||||
Power consumption | 100 to 240 VAC: 6.5 VA max.
12 to 24 VDC: 0.6 W max. |
||||
Dimensions | 72 x 36 x 66 mm (W x H x D) | ||||
Mounting method | Flush mounting | ||||
External connections | Screw terminals | ||||
Degree of protection | Panel surface: IP66 with oil resistance, NEMA 4 (indoors).
Panel surface only: IEC IP66. IEC IP66 |
||||
Display | 7-segment, negative transmissive LCD (with red backlight) | ||||
Digits | 6 digits (15-mm-high characters) | 8 digits (12-mm-high characters) | |||
Function | Total counter/time counter (selected via
DIP switch) |
Total counter | |||
Input mode | Up/down (individual) (total counter),
or accumulative (time counter) |
Up/down (individual) | |||
Max. counting speeds | 30 Hz or 5 kHz (selected via DIP switch) | ||||
Counting range | -99999 to 999999 | -9999999 to 99999999 | |||
Time specification | 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s
(selected via DIP switch) |
--- | |||
Timing accuracy | ±100 ppm (-10°C to 55°C) | --- | |||
Memory backup | EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min. | ||||
Input | Input signals | Count 1/start, count 2/gate, reset, and key protection *2 | |||
Input method | No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected
via DIP switch) |
||||
Count, start,
gate, reset |
No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 kΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. |
||||
Key protection | No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 0.5 VDC max. Open (OFF) impedance: 100 kΩ min. |
||||
Input
response speed |
Reset | Time counter: 20 ms; total counter: 20 ms or 1 ms (automatically switched according to
counting speed) |
|||
Start | Time counter: 20 ms | ||||
Key protection | Approx. 1 s | Approx. 1 s | |||
Reset system | External and manual resets |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
---|---|
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-
carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current- carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) |
Impulse withstand
voltage |
3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) |
Noise immunity | ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
Static immunity | Display: Malfunction: 8 kV, Destruction: 15 kV
DIP switch: Malfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions |
Shock resistance | Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions |
Ambient temperature | Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
EMC | (EMI) EN61326-1 *1
Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61326-1 *1 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) |
Approved standards | UL508 *2, CSA C22.2 No.14 *2, conforms to EN61010-1, VDE0106/P100 |
Case color | Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) |
Weight | Approx. 115 g |
last update: July 20, 2016