Programmable Terminal
            
        
last update: April 1, 2025
| Item | Specification | ||||
|---|---|---|---|---|---|
| NA5-15W | NA5-12W | NA5-9W | NA5-7W | ||
| Display panel
 *1  | 
Display device | TFT LCD | |||
| Screen size | 15.4 inches | 12.1 inches | 9.0 inches | 7.0 inches | |
| Resolution | 1,280 × 800 dots (horizontal × vertical) | 800 × 480 dots (horizontal × vertical) | |||
| Colors | 16,770,000 colors (24 bit full colors) | ||||
| Effective display
 area  | 
331 × 207 mm
 (horizontal × vertical)  | 
261 × 163 mm
 (horizontal × vertical)  | 
197 × 118 mm
 (horizontal × vertical)  | 
152 × 91 mm
 (horizontal × vertical)  | 
|
| View angles | Left: 60°, Right: 60°, Top: 60°, Bottom: 60° | ||||
| Backlight *2 | Life | 50,000 hours min. *3 | |||
| Brightness
 adjustment  | 
200 levels | ||||
| Type | LED | ||||
| Front panel
 indicators *4  | 
RUN | Lit green: Normal operation Lit red: Error | |||
| Model | Standard range | 
|---|---|
| NA5-15W[][][][]-V1
 NA5-12W[][][][]-V1 NA5-9W[][][][]-V1 NA5-7W[][][][]-V1  | 
Number of light and dark pixels: 10 or less. (There must not be 3 consecutive light/dark pixels.) | 
| Item | Specification | |||
|---|---|---|---|---|
| NA5-15W | NA5-12W | NA5-9W | NA5-7W | |
| Touch panel | Method: Analog resistive membrane type | |||
| Resolution: 16,384 × 16,384 | ||||
| Life: 1,000,000 operations | ||||
| Function keys *1 | 3 inputs (capacitance inputs) | |||
| Item | Specification | |||
|---|---|---|---|---|
| NA5-15W | NA5-12W | NA5-9W | NA5-7W | |
| User data capacity | 256 MB | |||
| Item | Specifications (Same for all models.) | |
|---|---|---|
| Ethernet
 ports  | 
Applications | Port 1: Connecting to anything other than the Sysmac Studio, e.g., device
 connections and VNC clients Port 2: Connecting to the Sysmac Studio in addition to the applications of port 1.  | 
| Number of ports | 2 ports | |
| Compliant standards | IEEE 802.3i (10BASE-T), IEEE 802.3u (100BASE-TX), and IEEE 802.3ab
 (1000Base-T)  | 
|
| Transmission media | Shielded twisted-pair (STP) cable: Category 5, 5e, or higher | |
| Transmission distance | 100 m | |
| Connector | RJ-45 8P8C modular connector | |
| USB host
 ports *1 *2  | 
Applications | USB Memory Device, keyboard, or mouse | 
| Number of ports | 2 ports | |
| Compliant standards | USB 2.0 | |
| Transmission distance | 5 m max. | |
| Connector | Type-A connector | |
| USB slave
 port *1  | 
Applications | Sysmac Studio connection | 
| Number of ports | 1 port | |
| Compliant standards | USB 2.0 | |
| Transmission distance | 5 m max. | |
| Connector | Type-B connector | |
| Serial port | Applications | Device Connection | 
| Number of ports | 1 port | |
| Compliant standards | RS-232C | |
| Transmission distance | 15 m max. | |
| Connector | D-DUB 9-pin female connector | |
| SD Memory
 Card slot  | 
Applications | To transfer or store the project or to store log data. | 
| Number of slots | 1 slot | |
| Compliant standards | SD/SDHC | |
            *1. Connection to all USB 2.0-compliant devices is not guaranteed.
*2. Use a USB memory for temporary applications such as transferring data.
        
| Item | Specification | |||
|---|---|---|---|---|
| NA5-15W | NA5-12W | NA5-9W | NA5-7W | |
| Rated supply voltage | 24 VDC | |||
| Allowable power
 supply voltage range  | 
19.2 to 28.8 VDC (24 VDC ±20%) | |||
| Allowable
 momentary power interruption time  | 
Operation for momentary power interruption is not specified. | |||
| Power consumption | 29 W max. | 25 W max. | 23 W max. | 19 W max. | 
| Ambient operating
 temperature  | 
0 to 50°C *1 *2 | |||
| Ambient storage
 temperature  | 
-20 to +60°C *3 | |||
| Ambient operating
 humidity  | 
10 to 90% *2
 Must be no condensation.  | 
|||
| Atmosphere | Must be free from corrosive gases. | |||
| Pollution degree | 2 or less: Meets IEC 61010-2-201. | |||
| Noise immunity | 2 kV on power supply line (Conforms to IEC 61000-4-4.) | |||
| Vibration resistance
 (during operation)  | 
Conforms to IEC 60068-2-6.
 5 to 8.4 Hz with 3.5 mm half amplitude and 8.4 to 150 Hz with 9.8 m/s2 for 100 minutes each in X, Y, and Z directions (Time coefficient of 10 minutes × coefficient factor of 10 = total time of 100 min.)  | 
|||
| Shock resistance
 (during operation)  | 
Conforms to IEC 60028-2-27.
 147 m/s2 3 times each in X, Y, and Z directions  | 
|||
| Dimensions | 420 × 291 × 69 mm
 (W × H × D)  | 
340 × 244 × 69 mm
 (W × H × D)  | 
290 × 190 × 69 mm
 (W × H × D)  | 
236 × 165 × 69 mm
 (W × H × D)  | 
| Panel cutout
 dimensions  | 
392 +1,0 ×
 268 +1,0 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4  | 
310 +1,0 ×
 221 +1,0 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4  | 
261 +1,0 ×
 166 +1,0 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4  | 
197 +0.5,0 ×
 141 +0.5,0 mm (horizontal × vertical) Panel thickness: 1.6 to 6.0 mm *4  | 
| Weight | 3.2 kg max. | 2.4 kg max. | 1.8 kg max. | 1.4 kg max. | 
| Degree of
 protection  | 
IP65 oil-proof type, UL Type 4X *4 (Front-panel controls)
 To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of the rubber packing.  | 
|||
| Battery life | Battery life: 5 years at 25°C
 The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up by a super capacitor for 5 minutes after removing the old battery. (This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.)  | 
|||
| International
 standards *5  | 
EU
 UKCA Shipbuilding standards LR, DNV, and UK IP65 oil-proof, UL Type 4X *4 (Front-panel controls) cULus KC RCM  | 
|||
       
    
            *1. The ambient operating temperature is subject to the following restrictions, depending on the mounting angle.
• The ambient operating temperature is 0° to 40°C when the mounting angle is 0° or more and less than 45° to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 45° or more and 90° or less to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 90° or more and 135° or less to the horizontal.
        
*2. Use the Programmable Terminal within the following temperature and humidity ranges.
       
    *3. Store the Programmable Terminal within the following temperature and humidity ranges.
       
    
            *4. Use the NA-[]WATW01 High-pressure Waterproof Attachment (sold separately) to conform to UL Type 4X.
       When the NA-[]WATW01 High-pressure Waterproof Attachment is used, the panel thickness is between 1.6 to 4.5 mm.
*5. Check with your OMRON representative or refer to the following OMRON website for the latest information on the
       applicable standards for each model: www.ia.omron.com.
*6. Use power supply Class 2 to conform to UL Standards.
        
NA series and Programming Devices
| NA series | Corresponding unit versions/version | ||
|---|---|---|---|
| Model | NA system version | NJ/NX/NY-series Controller
 NX701-[][][][] NY512-[][][][] NX502-[][][][] NY532-[][][][] NX102-[][][][] NJ501-[][][][] NX1P2-[][][][] NJ301-[][][][] NX-CSG320 NJ101-[][][][]  | 
Sysmac studio | 
| NA5-[][][][][][]-V1 | 1.17 or later | NX502: 1.60 or later | 1.54 or higher | 
| 1.10 or later | NX-CSG320: 1.00 or later | 1.24 or higher | |
| 1.09 or later | NX102: 1.30 or later | 1.23 or higher | |
| 1.08 or later | NX1P2: 1.13 or later
 NY512: 1.12 or later NY532: 1.12 or later NX701: 1.10 or later NJ101: 1.10 or later NJ501: 1.01 or later NJ501 Database Connection: 1.05 or later NJ301: 1.01 or later  | 
1.40 or higher | |
| Manufacturer | Models | Connection method | Communications driver | 
|---|---|---|---|
| OMRON | NX102-[][][][]
 NX1P2-[][][][] NX502-[][][][] NX701-[][][][] NJ501-[][][][] NJ301-[][][][] NJ101-[][][][] NY512-[][][][] NY532-[][][][] NX-CSG320  | 
Built-in EtherNet/IP port | Ethernet | 
| NX502-[][][][] | NX-EIP201 | ||
| CJ2H-CPU64/65/66/67/68-EIP
 CJ2M-CPU31/32/33/34/35  | 
Built-in EtherNet/IP port | CIP Ethernet | |
| CJ2H-CPU64/65/66/67/68
 CJ2M-CPU11/12/13/14/15  | 
CJ1W-EIP21S | ||
| CJ2H-CPU64/65/66/67/68-EIP
 CJ2M-CPU31/32/33/34/35  | 
CJ1W-EIP21 *1 | ||
| CJ2H-CPU64/65/66/67/68-EIP
 CJ2M-CPU31/32/33/34/35  | 
Built-in EtherNet/IP port | FINS Ethernet | |
| CJ1H-CPU65H/66H/67H
 CJ1H-CPU65H/66H/67H-R CJ1G-CPU42H/43H/44H/45H CJ1M-CPU11/12/13/21/22/23 CJ2H-CPU64/65/66/67/68(-EIP) CJ2M-CPU11/12/13/14/15 CJ2M-CPU31/32/33/34/35  | 
CJ1W-ETN21 *1
 CJ1W-EIP21 *1  | 
||
| CJ2H-CPU64/65/66/67/68
 CJ2M-CPU11/12/13/14/15  | 
CJ1W-EIP21S | ||
| CS1G-CPU42H/43H/44H/45H
 CS1H-CPU63H/64H/65H/66H/67H  | 
CS1W-ETN21 *1
 CS1W-EIP21 *1  | 
||
| CS1G-CPU43H/44H/45H
 CS1H-CPU63H/64H/65H/66H/67H  | 
CS1W-EIP21S | ||
| CS1D-CPU65H/67H/67HA/68HA/44SA/67SA | CS1W-ETN21 *1
 CS1D-ETN21D CS1W-EIP21 *1 CS1W-EIP21S  | 
||
| CP1H-[][][][][]-[] | CP1W-CIF41 | ||
| CP1L-[][][][][]-[]
 CP2E-N[][]D[]-[]  | 
Built-in Ethernet port
 CP1W-CIF41  | 
||
| CK3E-1[]10
 CK3M-CPU1[]1  | 
Built-in Ethernet port | Modbus/TCP | |
| CS1G-CPU42H/43H/44H/45H
 CS1H-CPU63H/64H/65H/66H/67H CS1D-CPU65H/67H/67HA/68HA/44SA/57SA  | 
Built-in RS-232C port
 CS1W-SCB21-V1 CS1W-SCB41-V1 CS1W-SCU21-V1 CS1W-SCU31-V1  | 
Host Link | |
| CJ2H-CPU64/65/66/67/68(-EIP)
 CJ2M-CPU11/12/13/14/15/31/32/33/34/35  | 
Built-in RS-232C port
 CJ1W-SCU22 CJ1W-SCU32 CJ1W-SCU42  | 
||
| CP1L-[][][][][]-[]
 CP1H-[][][][][]-[]  | 
CP1W-CIF01
 CP1W-CIF11 CP1W-CIF12-V1  | 
||
| CP2E-[][][]D[]-[] | Built-in RS-232C port
 CP1W-CIF01 CP1W-CIF11 CP1W-CIF12-V1 CP2W-CIFD1 CP2W-CIFD2  | 
*1. Product no longer available to order.
| Manufacturer | Models | Connection method | Communications driver | 
|---|---|---|---|
| OMRON | NX102-[][][][]
 NX1P2-[][][][] NX502-[][][][] NX701-[][][][] NJ501-[][][][] NJ301-[][][][] NJ101-[][][][] NY512-[][][][] NY532-[][][][] NX-CSG320  | 
Built-in EtherNet/IP port | Ethernet | 
| NX502-[][][][] | NX-EIP201 | 
last update: April 1, 2025