Page top

Industrial Automation

Industrial Automation

XW2K

Ultra-Compact Interface Wiring System

XW2K

The Industry’s Smallest*1 Compact Interface Wiring System to Reduce Work and Save Space on Control Panels. *1. Results of OMRON survey conducted in March, 2022

For PLC Connection

Ratings

For OMRON, Yokogawa Electric, or Hitachi Industrial Equipment Systems PLC Connection

Rated voltage 30 VDC
Rated current I/O unit signal line: 0.5 A, I/O unit common line: 4 A, Power supply line: 7 A
Applicable wire
*1
Stranded wire,
solid wire
0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*1. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.

For Mitsubishi Electric, Fuji Electric, or KEYENCE PLC Connection

Rated voltage 30 VDC
Rated current I/O unit signal line: 0.5 A, I/O unit common line: 1 A/2 A, Power supply line: 7 A
Applicable wire
*1
Stranded wire,
solid wire
0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*1. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.

For PLC Connection (Integrated Common Terminal Type)

Ratings

For OMRON PLC Connection

Rated voltage 30 VDC
Rated current I/O unit signal line: 0.5 A, I/O unit common line: 2 A, Power supply line: 4 A
Applicable wire
*1
Stranded wire,
solid wire
0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*1. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.

For OMRON, Yokogawa Electric, or Hitachi Industrial Equipment Systems PLC Connection

Rated voltage 30 VDC
Rated current I/O unit signal line: 0.5 A, I/O unit common line: 4 A, Power supply line: 7 A
Applicable wire
*2
Stranded wire,
solid wire
0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*2. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.

For Mitsubishi Electric or Fuji Electric PLC Connection

Rated voltage 30 VDC
Rated current I/O unit signal line: 0.5 A, I/O unit common line: 2 A, Power supply line: 7 A
Applicable wire
*1
Stranded wire,
solid wire
0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*1. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.

For KEYENCE PLC Connection

Rated voltage 30 VDC
Rated current I/O unit signal line: 0.5 A, I/O unit common line: 2 A, Power supply line: 7 A
Applicable wire
*1
Stranded wire,
solid wire
0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*1. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.

General-Purpose

Ratings

Rated voltage 125 VAC, 30 VDC *1
Rated current 1 A
Applicable wire *2 Stranded wire, solid wire 0.08 to 1.5 mm2 (AWG 28 to 16)
Ferrules With insulation sleeve: 0.14 to 0.5 mm2 (AWG 26 to 20)
Without insulation sleeve: 0.75 to 1.5 mm2 (AWG 18 to 16)

*1. Only "30 VDC" is printed on the main unit.
*2. Outer diameter of insulation must be 2.8 mm max.

Refer to Data Sheet for information on recommended ferrules and crimp tools.
Refer to the common items (Data Sheet) for details on performance.