Compact Photoelectric Sensor with Stainless Steel Housing
last update: February 1, 2022
Sensing method | Through-beam | Retro-reflective
with MSR function |
Diffuse-reflective
Models |
||
---|---|---|---|---|---|
Model | NPN output | E3ZM-T61
E3ZM-T66 |
E3ZM-T63
E3ZM-T68 |
E3ZM-R61
E3ZM-R66 |
E3ZM-D62
E3ZM-D67 |
PNP output | E3ZM-T81
E3ZM-T86 |
E3ZM-T83
E3ZM-T88 |
E3ZM-R81
E3ZM-R86 |
E3ZM-D82
E3ZM-D87 |
|
Sensing distance | 15 m | 0.8 m | 4 m [100 mm]
(Using E39-R1S) 3 m [100 mm] (Using E39-R1) |
1 m
(White paper 300 × 300 mm) |
|
Spot diameter (typical) | --- | ||||
Standard sensing object | Opaque: 12-mm dia.
min. |
Opaque: 2-mm dia.
min. |
Opaque: 75-mm dia.
min. |
--- | |
Differential travel | --- | 20% of sensing
distance max. |
|||
Black/white error | --- | ||||
Directional angle | Emitter, Receiver: 3° to 15° | Sensor: 3° to 10°
Reflector: 30° |
--- | ||
Light source (wavelength) | Infrared LED (870 nm) | Red LED (660 nm) | Infrared LED (870 nm) | ||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | ||||
Current consumption | 40 mA max. (Emitter 20 mA max.,
Receiver 20 mA max.) |
25 mA max. | |||
Control output | Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage:
2 V max.) Open-collector output (NPN/PNP output depending on model) Light-ON/Dark-ON switch selectable |
||||
Protection circuits | Reversed power supply polarity
protection, Output short-circuit protection, and Reversed output polarity protection |
Reversed power supply polarity protection,
Output short-circuit protection, Mutual interference prevention, and Reversed output polarity protection |
|||
Response time | Operate or reset: 1 ms max. | ||||
Sensitivity adjustment | One-turn adjuster | ||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | ||||
Ambient temperature range | Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | ||||
Insulation resistance | 20 MΩ min. at 500 VDC | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | ||||
Degree of protection * | IEC: IP67, DIN 40050-9: IP69K | ||||
Connection method | Pre-wired cable (standard length: 2 m)
M8 4-pin Connector |
||||
Indicator | Operation indicator (yellow), Stability indicator (green) (Emitter has only power supply
indicator (green).) |
||||
Weight
(packed state) |
Pre-wired
models (with 2-m cable) |
Approx. 150 g | Approx. 90 g | ||
Connector
models |
Approx. 60 g | Approx. 40 g | |||
Materials | Case | SUS316L | |||
Lens | PMMA (polymethylmethacrylate) | ||||
Display | PEI (Polyetherimide) | ||||
Sensitivity
adjustment and mode selector switch |
PEEK (polyetheretherketone) | ||||
Seals | Fluoro rubber | ||||
Accessories | Instruction sheet (Note: Reflectors and Mounting Brackets are sold separately.) |
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method | BGS Reflective Models | |||
---|---|---|---|---|
Model | NPN output | E3ZM-LS61H
E3ZM-LS66H |
E3ZM-LS62H
E3ZM-LS67H |
E3ZM-LS64H
E3ZM-LS69H |
PNP output | E3ZM-LS81H
E3ZM-LS86H |
E3ZM-LS82H
E3ZM-LS87H |
E3ZM-LS84H
E3ZM-LS89H |
|
Sensing distance | 10 to 100 mm
(White paper 100 × 100 mm) |
10 to 150 mm
(White paper 100 × 100 mm) |
10 to 200 mm
(White paper 100 × 100 mm) |
|
Spot diameter (typical) | 4-mm dia. at sensing
distance of 100 mm |
12-mm dia. at sensing
distance of 150 mm |
18-mm dia. at sensing
distance of 200 mm |
|
Standard sensing object | --- | |||
Differential travel | 3% of sensing distance max. | 15% of sensing distance max. | 20% of sensing distance max. | |
Black/white error | 5% of sensing distance max. | 10% of sensing distance max. | 20% of sensing distance max. | |
Directional angle | --- | |||
Light source
(wavelength) |
Red LED (650 nm) | Red LED (660 nm) | ||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||
Current consumption | 25 mA max. | |||
Control output | Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V
max.) Open-collector output (NPN/PNP output depending on model) Light-ON/Dark-ON cable connection selectable |
|||
Protection circuits | Reversed power supply polarity protection, Output short-circuit protection, Reversed output
polarity protection, Mutual interference protection |
|||
Response time | Operate or reset: 1 ms max. | |||
Sensitivity adjustment | --- | |||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |||
Ambient temperature
range |
Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | |||
Insulation resistance | 20 MΩ min. at 500 VDC | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection * | IEC: IP67, DIN 40050-9: IP69K | |||
Connection method | Pre-wired cable (standard length: 2 m)
M8 4-pin Connector |
|||
Indicator | Operation indicator (yellow), Stability indicator (green) | |||
Weight
(packed state) |
Pre-wired
models (with 2-m cable) |
Approx. 90 g | ||
Connector
models |
Approx. 40 g | |||
Materials | Case | SUS316L | ||
Lens | PMMA (polymethylmethacrylate) | |||
Display | PEI (Polyetherimide) | |||
Seals | Fluoro rubber | |||
Accessories | Instruction sheet (Note: Mounting Brackets are sold separately.) |
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
last update: February 1, 2022