Smart Fiber Amplifier Units
            
        
last update: April 7, 2025
| Type | Standard models/
 Enhanced timer function models  | 
External input models | |||
|---|---|---|---|---|---|
| Item | NPN output | E3X-ZV11 | E3X-ZV6/ZV6M | E3X-ZV21 | E3X-ZV7 | 
| PNP output | E3X-ZV41 | E3X-ZV8/ZV8M | E3X-ZV51 | E3X-ZV9 | |
| Connecting
 method  | 
Pre-wired | Wire-saving
 Connector *1  | 
Pre-wired | Wire-saving
 Connector *1  | 
|
| Inputs/outputs | 1 output | 1 output + 1 input *2 | |||
| Light source (wavelength) | Red, 4-element LED (625 nm) | ||||
| Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% max. | ||||
| Power consumption | Normal mode: 720 mW max.
 (Power supply voltage 24 V: Current consumption 30 mA max. / Power supply voltage 12 V: Current consumption 60 mA max.) Eco function ON: 530 mW max. (Power supply voltage 24 V: Current consumption 22 mA max. / Power supply voltage 12 V: Current consumption 44 mA max.)  | 
Normal mode: 720 mW max.
 (Power supply voltage 24 V: Current consumption 30 mA max. / Power supply voltage 12 V: Current consumption 60 mA max.) Eco function ON: 530 mW max. (Power supply voltage 24 V: Current consumption 22 mA max. / Power supply voltage 12 V: Current consumption 44 mA max.) Eco function Standby: 390 mW max. (Power supply voltage 24 V: Current consumption 16 mA max./ Power supply voltage 12 V: Current consumption 32 mA max.)  | 
|||
| Control output | Load power supply voltage: 26.4 VDC, open collector output type
 (NPN or PNP output differs depending on the type.) Load current: 100 mA max. (Residual voltage: Load current less than 10 mA: 1 V max., load current 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max.  | 
||||
| Indicators | 7-segment displays
 (Threshold Level display: green, Incident Light Level display: red) Display direction: Switchable between normal and reversed. Smart Tuning Indicator (green) OUT indicator (orange)  | 
||||
| Protection circuits | Power supply reverse polarity protection, output short-circuit protection
 and output reverse polarity protection  | 
||||
| Response time | Super-
 highspeed mode (SHS)  | 
Operate or reset: 50 μs | |||
| High-speed
 mode (HS)  | 
Operate or reset: 250 μs *3 | ||||
| Standard
 mode (Stnd)  | 
Operate or reset: 1 ms *4 | ||||
| Giga-power
 mode (GIGA)  | 
Operate or reset: 16 ms | ||||
| Sensitivity adjustment | Smart Tuning (2-point tuning, power tuning, percentage tuning (-99% to 99%),
 maximum sensitivity tuning, full auto tuning, position tuning) or manual adjustment  | 
||||
| Mutual interference prevention
 function  | 
Emission cycle setting switching type (up to 4 units) | ||||
| Functions | DPC (Dynamic
 Power Control)  | 
Yes | |||
| ATC
 (Active Threshold Control)  | 
Yes | ||||
| Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot or On/Off-delay Timer *5
 E3X-ZV11/41/6/8/21/7/9: 1 to 9,999 ms E3X-ZV6M/8M: 0.1 to 9,999 ms  | 
||||
| Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
| Resetting
 settings  | 
Select from initial reset (factory defaults) or user reset (saved settings). | ||||
| Eco mode | Select from OFF (digital display lit)
 and Eco ON (digital display not lit).  | 
Select from OFF (digital display lit),
 Eco ON (digital display not lit) and Standby (digital display not lit, emission stop).  | 
|||
| Power tuning | Select from ON or OFF. | ||||
| Ambient illumination
 (Receiver side)  | 
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
| Ambient temperature range | Operating: -25°C to 55°C
 Storage: -30°C to 70°C (with no icing or condensation)  | 
||||
| Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding
 air temperature range shown above  | 
||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
| Vibration resistance
 (destruction)  | 
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance
 (destruction)  | 
500 m/s2 for 3 times each in X, Y, and Z directions | ||||
| Weight
 (packed state/Sensor only)  | 
Approx. 95 g/
 approx. 65 g  | 
Approx. 45 g/
 approx. 20 g  | 
Approx. 95 g/
 approx. 65 g  | 
Approx. 45 g/
 approx. 20 g  | 
|
| Materials | Case | Polycarbonate (PC). | |||
| Cover | Polycarbonate (PC) | ||||
| Cable | PVC | ||||
| MTTFd (Year) | 298 | E3X-ZV6/8: 298
 E3X-ZV6M/8M: 296  | 
263 | 250 | |
| Accessories | Instruction manual, Compliance sheet | ||||
            *1. One of the E3X-CN11 (bus-connector with 3 wires), E3X-CN12 (sub-connector with 1 wires)
*2. The following details apply to the input.
        
| Contact input (relay or switch) | Non-contact input (transistor) | Input time | |
|---|---|---|---|
| NPN | ON: Shorted to 0 V
 (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc.  | 
ON: 1.5 V max.
 (Sourcing current: 1 mA max.) OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)  | 
ON: 100 ms min.
 OFF: 100 ms min.  | 
| PNP | ON: Shorted to Vcc
 (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V.  | 
ON: Vcc - 1.5 V to Vcc
 (Sinking current: 3 mA max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.)  | 
            *3. Mutual interference prevention function in the Response Time Priority Mode: 2 units: 350 μs; 3 units: 400 μs / In the Unit Number Priority Mode: 4 units: 700 μs
*4. Mutual interference prevention function in the Unit Number Priority Mode: 4 units: 1.6 ms
*5. Only E3X-ZV6M/ZV8M can be selected.
        
| Type | Standard models | External input models | ||
|---|---|---|---|---|
| Item | NPN output | E3X-MZV11 | E3X-MZV6 | E3X-MZV21 | 
| PNP output | E3X-MZV41 | E3X-MZV8 | E3X-MZV51 | |
| Connecting
 method  | 
Pre-wired | Wire-saving
 Connector *1  | 
Pre-wired | |
| Inputs/outputs | 2 output | 2 outputs + 2 inputs *2 | ||
| Light source (wavelength) | Red, 4-element LED (625 nm) | |||
| Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% max. | |||
| Power consumption | Normal mode: 820 mW max.
 (Power supply voltage 24 V: Current consumption 35 mA max. / Power supply voltage 12 V: Current consumption 69 mA max.) Eco function ON: 600 mW max. (Power supply voltage 24 V: Current consumption 25 mA max. / Power supply voltage 12 V: Current consumption 50 mA max.)  | 
Normal mode: 820 mW max.
 (Power supply voltage 24 V: Current consumption 35 mA max. / Power supply voltage 12 V: Current consumption 69 mA max.) Eco function ON: 600 mW max. (Power supply voltage 24 V: Current consumption 25 mA max. / Power supply voltage 12 V: Current consumption 50 mA max.) Eco function Standby: 480 mW max. (Power supply voltage 24 V: Current consumption 20 mA max. / Power supply voltage 12 V: Current consumption 40 mA max.)  | 
||
| Control output | Load power supply voltage: 26.4 VDC, open collector output type
 (NPN or PNP output differs depending on the type.) Load current: 100 mA max. (Residual voltage: Load current less than 10 mA: 1 V max., load current 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max.  | 
|||
| Indicators | 7-segment displays
 (Threshold Level display: green, Incident Light Level display: red) Display direction: Switchable between normal and reversed. Smart Tuning Indicator (green) OUT1/2 indicator (orange), CH Indicator (green)  | 
|||
| Protection circuits | Power supply reverse polarity protection, output short-circuit protection
 and output reverse polarity protection  | 
|||
| Response time | Super-highspeed mode (SHS) | Operate or reset: 100 μs | ||
| High-speed mode (HS) | Operate or reset: 250 μs *3 | |||
| Standard mode (Stnd) | Operate or reset: 1 ms *4 | |||
| Giga-power mode (GIGA) | Operate or reset: 16 ms | |||
| Sensitivity adjustment | Smart Tuning (2-point tuning, power tuning, percentage tuning (-99% to 99%), maximum sensitivity tuning, full auto tuning, position tuning) or manual adjustment | |||
| Mutual interference prevention function | Emission cycle setting switching type (up to 2 units)
 Or, up to 2 units for E3X-ZV (the Unit Number Priority Mode), and 1 unit for E3X-MZV.  | 
|||
| Functions | DPC
 (Dynamic Power Control)  | 
Yes | ||
| ATC
 (Active Threshold Control)  | 
Yes | |||
| Timer | Select from timer disabled, OFF-delay, ON-delay or one-shot timer: 1 to 9,999 ms | |||
| Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||
| Resetting settings | Select from initial reset (factory defaults) or user reset (saved settings). | |||
| Eco mode | Select from OFF (digital display lit)
 and Eco ON (digital display not lit).  | 
Select from OFF (digital display lit),
 Eco ON (digital display not lit) and Standby (digital display not lit, emission stop).  | 
||
| Power tuning | Select from ON or OFF. | |||
| Ambient illumination
 (Receiver side)  | 
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||
| Ambient temperature range | Operating: -25°C to 55°C
 Storage: -30°C to 70°C (with no icing or condensation)  | 
|||
| Ambient humidity range | Operating and storage: 35 to 85% (with no condensation)
 within the surrounding air temperature range shown above  | 
|||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
| Vibration resistance
 (destruction)  | 
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y,
 and Z directions  | 
|||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
| Weight
 (packed state/Sensor only)  | 
Approx. 100 g/
 approx. 75 g  | 
Approx. 45 g/
 approx. 20 g  | 
Approx. 100 g/approx. 75 g | |
| Materials | Case | Polycarbonate (PC). | ||
| Cover | Polycarbonate (PC) | |||
| Cable | PVC | |||
| MTTFd (Year) | 222 | 216 | ||
| Accessories | Instruction manual, Compliance sheet | |||
            *1. One of the E3X-CN21 (bus-connector with 4 wires), E3X-CN22 (sub-connector with 2 wires)
*2. The following details apply to the input.
        
| Contact input (relay or switch) | Non-contact input (transistor) | Input time | |
|---|---|---|---|
| NPN | ON: Shorted to 0 V
 (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc.  | 
ON: 1.5 V max.
 (Sourcing current: 1 mA max.) OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)  | 
ON: 100 ms min.
 OFF: 100 ms min.  | 
| PNP | ON: Shorted to Vcc
 (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V.  | 
ON: Vcc - 1.5 V to Vcc
 (Sinking current: 3 mA max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.)  | 
            *3. When using Mutual interference prevention function: 700 μs
*4. When using Mutual interference prevention function: 1.6 ms
        
| Sensing
 method  | 
Sensing
 direction  | 
Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Through-beam | Right-angle | M4 | E32-T11N 2M | 2,000 | 1,000 | 700 | 280 | 
| E32-LT11N 2M | 4,000 * | 3,500 | 2,300 | 920 | |||
| Straight | E32-T11R 2M | 2,000 | 1,000 | 700 | 280 | ||
| E32-LT11 2M | 4,000 * | 4,000 * | 2,700 | 1,080 | |||
| E32-LT11R 2M | 4,000 * | 3,500 | 2,300 | 920 | |||
| Reflective | Right-angle | M3 | E32-C31N 2M | 110 | 50 | 46 | 14 | 
| E32-C21N 2M | 290 | 130 | 90 | 39 | |||
| M4 | E32-D21N 2M | 840 | 350 | 240 | 100 | ||
| M6 | E32-C11N 2M | 780 | 350 | 320 | 100 | ||
| E32-LD11N 2M | 840 | 350 | 240 | 100 | |||
| Straight | M3 | E32-D21R 2M | 140 | 60 | 40 | 16 | |
| E32-C31 2M | 330 | 150 | 100 | 44 | |||
| E32-C31M 1M | |||||||
| M4 | E32-D211R 2M | 140 | 60 | 40 | 16 | ||
| M6 | E32-D11R 2M | 840 | 350 | 240 | 100 | ||
| E32-CC200 2M | 1,400 | 600 | 400 | 180 | |||
| E32-LD11 2M | 860 | 360 | 250 | 110 | |||
| E32-LD11R 2M | 840 | 350 | 240 | 100 | |||
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
| Sensing
 method  | 
Size | Sensing
 direction  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Through-beam | 1 dia. | Top-view | E32-T223R 2M | 450 | 250 | 150 | 60 | 
| 1.5 dia. | E32-T22B 2M | 680 | 400 | 220 | 90 | ||
| 3 dia. | E32-T12R 2M | 2,000 | 1,000 | 700 | 280 | ||
| Side-view | E32-T14LR 2M | 750 | 450 | 260 | 100 | ||
| Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 140 | 60 | 40 | 16 | 
| 1.5 dia. +
 0.5 dia.  | 
E32-D43M 1M | 28 | 12 | 8 | 4 | ||
| 3 dia. | E32-D22R 2M | 140 | 60 | 40 | 16 | ||
| E32-D221B 2M | 300 | 140 | 90 | 40 | |||
| E32-D32L 2M | 700 | 300 | 200 | 90 | |||
| 3 dia. +
 0.8 dia.  | 
E32-D33 2M | 70 | 30 | 20 | 8 | ||
| Sensing
 method  | 
Sensing
 direction  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
|||
| Through-beam | Top-view | E32-T15XR 2M | 2,000 | 1,000 | 700 | 280 | 
| Side-view | E32-T15YR 2M | 750 | 450 | 260 | 100 | |
| Flat-view | E32-T15ZR 2M | |||||
| Reflective | Top-view | E32-D15XR 2M | 840 | 350 | 240 | 100 | 
| Side-view | E32-D15YR 2M | 200 | 100 | 52 | 24 | |
| Flat-view | E32-D15ZR 2M | |||||
| Sensing
 method  | 
Sensing
 direction  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
|||
| Through-beam | Side-view | E32-T24R 2M | 170 | 100 | 50 | 20 | 
| E32-T24E 2M | 450 | 250 | 150 | 60 | ||
| Top-view | E32-T33 1M | 150 | 90 | 50 | 20 | |
| E32-T21-S1 2M | 510 | 300 | 170 | 68 | ||
| E32-TC200BR 2M | 2,000 | 1,000 | 700 | 280 | ||
| Reflective | Side-view | E32-D24R 2M | 70 | 30 | 20 | 8 | 
| E32-D24-S2 2M | 120 | 53 | 45 | 14 | ||
| Top-view | E32-D43M 1M | 28 | 12 | 8 | 4 | |
| E32-D331 2M | 14 | 6 | 4 | 2 | ||
| E32-D33 2M | 70 | 30 | 20 | 8 | ||
| E32-D32-S1 0.5M | 63 | 27 | 18 | 7 | ||
| E32-D31-S1 0.5M | ||||||
| E32-DC200F4R 2M | 140 | 60 | 40 | 16 | ||
| E32-D22-S1 2M | 250 | 110 | 72 | 30 | ||
| E32-D21-S3 2M | ||||||
| E32-DC200BR 2M | 840 | 350 | 240 | 100 | ||
| E32-D25-S3 2M | 250 | 110 | 72 | 30 | ||
| Type | Spot
 diameter  | 
Center
 distance (mm)  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Variable
 spot  | 
0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M+E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
| 0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M+E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
| Parallel
 light  | 
4 dia. | 0 to 20 | E32-C31 2M+E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
| E32-C31N 2M+E39-F3C | |||||||
| Integrated
 lens  | 
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
| 6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | ||||
| Small-spot | 0.1 dia. | 7 | E32-C41 1M+E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
| 0.5 dia. | E32-C31 2M+E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
| E32-C31N 2M+E39-F3A-5 | |||||||
| 0.2 dia. | 17 | E32-C41 1M+E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
| 0.5 dia. | E32-C31 2M+E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
| E32-C31N 2M+E39-F3B | |||||||
| 3 dia. | 50 | E32-CC200 2M+E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
| E32-C11N 2M+E39-F18 | |||||||
| Type | Sensing
 direction  | 
Aperture
 angle  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Through-beam
 models with integrated lens  | 
Right-angle | 15° | E32-LT11N 2M | 4,000 *2 | 3,500 | 2,300 | 920 | 
| Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 8,000 | |
| 15° | E32-LT11 2M | 4,000 *2 | 4,000 *2 | 2,700 | 1,080 | ||
| E32-LT11R 2M | 4,000 *2 | 3,500 | 2,300 | 920 | |||
| Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
| Through-beam
 models with lenses  | 
Right-angle | 12° | E32-T11N 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | 
| 6° | E32-T11N 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
| Top-view | 12° | E32-T11R 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | |
| 6° | E32-T11R 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
| Side-view | 60° | E32-T11R 2M+E39-F2 | 1,450 | 800 | 500 | 200 | |
| Top-view | 12° | E32-T11 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,860 | |
| 6° | E32-T11 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
| Side-view | 60° | E32-T11 2M+E39-F2 | 2,300 | 1,320 | 860 | 320 | |
| Top-view | 12° | E32-T51R 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 3,900 | 1,500 | |
| 6° | E32-T51R 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
| Side-view | 60° | E32-T51R 2M+E39-F2 | 1,400 | 720 | 500 | 200 | |
| Top-view | 12° | E32-T81R-S 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 2,700 | 1,000 | |
| 6° | E32-T81R-S 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
| Side-view | 60° | E32-T81R-S 2M+E39-F2 | 1,000 | 550 | 360 | 140 | |
| Top-view | 12° | E32-T61-S 2M+E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
| 6° | E32-T61-S 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,100 | ||
| Side-view | 60° | E32-T61-S 2M+E39-F2 | 1,680 | 900 | 600 | 240 | |
| Top-view | 12° | E32-T51 2M+E39-F1-33 | 4,000 *2 | 4,000 *2 | 2,300 | 1,400 | |
| 6° | E32-T51 2M+E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
| Reflective
 models with integrated lens  | 
Top-view | 4° | E32-D16 2M | 40 to 2,800 | 40 to 1,400 | 40 to 900 | 40 to 480 | 
            *1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
        
| Sensing
 method  | 
Sensing
 direction  | 
Aperture
 angle  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Through-
 beam  | 
Side-view | 1.5° | E32-A03 2M | 3,220 | 1,780 | 1,200 | 500 | 
| E32-A03-1 2M | |||||||
| 3.4° | E32-A04 2M | 1,280 | 680 | 450 | 200 | ||
| 4° | E32-T24SR 2M | 4,000 * | 2,200 | 1,460 | 580 | ||
| E32-T24S 2M | 4,000 * | 2,600 | 1,740 | 700 | |||
| E32-T22S 2M | 4,000 * | 3,800 | 2,500 | 1,000 | |||
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
| Sensing
 method  | 
Sensing
 direction  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
|||
| Limited-reflective | Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
| E32-L24S 2M | 0 to 4 | |||||
| Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
| Sensing
 method  | 
Feature | Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Retro-reflective | Film detection | M3 | E32-C31 2M
 +E39-F3R +E39-RP37  | 
250 | 200 | --- | |
| Square | --- | E32-R16 5M | 150 to 1,500 | ||||
| Threaded | M6 | E32-R21 2M | 10 to 250 | ||||
| Hex-shaped | E32-LR11NP 2M
 +E39-RP1  | 
1,350 | 1,200 | 1,000 | 550 | ||
| Sensing
 method  | 
Feature | Sensing
 direction  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Limited-
 reflective  | 
Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
| Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
| Glass substrate
 alignment, 70°C  | 
E32-A08 2M | 10 to 20 | --- | ||||
| Standard/long-distance | E32-A12 2M | 12 to 30 | --- | ||||
| Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
| Glass substrate
 mapping, 70°C  | 
Top-view | E32-A09 2M | 15 to 38 | --- | |||
| Sensing
 method  | 
Type | Sensing
 direction  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Through-
 beam  | 
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,200 | 
| Chemical/
 oil-resistant  | 
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,600 | |
| E32-T11F 2M | 4,000 *1 | 4,000 *1 | 2,600 | 1,000 | |||
| Side-view | E32-T14F 2M | 1,400 | 800 | 500 | 200 | ||
| Chemical/
 oil-resistant at 150°C  | 
Top-view | E32-T51F 2M | 4,000 *1 | 2,800 | 1,800 | 700 | |
| Reflective | Semiconductors:
 Cleaning, developing, and etching; 60°C  | 
Top-view | E32-L11FP 5M | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A Recommended sensing distance: 22 mm)  | 
|||
| Semiconductors:
 Resist stripping; 85°C  | 
E32-L11FS 5M | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)  | 
|||||
| Chemical/
 oil-resistant  | 
E32-D12F 2M | --- *2 | 190 | 130 | 60 | ||
| Chemical-
 resistant cable  | 
E32-D11U 2M | 840 | 350 | 240 | 100 | ||
            *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
        
| Sensing
 method  | 
Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
|||
| Through-beam | 1.5 dia. | E32-T22B 2M | 680 | 400 | 220 | 90 | 
| M3 | E32-T21 2M | |||||
| M4 | E32-T11 2M | 2,500 | 1,350 | 900 | 360 | |
| Square | E32-T25XB 2M | 500 | 300 | 170 | 70 | |
| Reflective | 1.5 dia. | E32-D22B 2M | 140 | 60 | 40 | 16 | 
| M3 | E32-D21 2M | |||||
| 3 dia. | E32-D221B 2M | 300 | 140 | 90 | 40 | |
| M4 | E32-D21B 2M | |||||
| M6 | E32-D11 2M | 840 | 350 | 240 | 100 | |
| Square | E32-D25XB 2M | 240 | 100 | 60 | 30 | |
| Sensing
 method  | 
Size | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
|||
| Through-beam | 100°C | E32-T51R 2M | 1,600 | 800 | 560 | 225 | 
| 150°C | E32-T51 2M | 2,800 | 1,500 | 1,000 | 400 | |
| 200°C | E32-T81R-S 2M | 1,000 | 550 | 360 | 140 | |
| 350°C | E32-T61-S 2M | 1,680 | 900 | 600 | 240 | |
| Reflective | 100°C | E32-D51R 2M | 670 | 280 | 190 | 80 | 
| 150°C | E32-D51 2M | 1,120 | 450 | 320 | 144 | |
| 200°C | E32-D81R-S 2M | 420 | 180 | 120 | 54 | |
| 300°C | E32-A08H2 2M | 10 to 20 | --- | |||
| E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
| 350°C | E32-D611-S 2M | 420 | 180 | 120 | 54 | |
| E32-D61-S 2M | ||||||
| 400°C | E32-D73-S 2M | 280 | 120 | 80 | 36 | |
| Sensing
 method  | 
Type | Sensing
 width  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Through-beam | Area | 11 mm | E32-T16PR 2M | 3,100 | 1,700 | 1,120 | 440 | 
| E32-T16JR 2M | 2,750 | 1,500 | 960 | 380 | |||
| 30 mm | E32-T16WR 2M | 4,000 * | 2,600 | 1,700 | 680 | ||
| Reflective | Array | 11 mm | E32-D36P1 2M | 700 | 300 | 200 | 90 | 
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
| Sensing
 method  | 
Tube
 diameter  | 
Feature | Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Tube-
 mounting  | 
3.2, 6.4,
 or 9.5 dia.  | 
Stable residual
 quantity detection  | 
E32-A01 5M | Applicable tube:
 Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm  | 
|||
| 8 to 10 dia. | Mounting at
 multiple levels  | 
E32-L25T 2M | Applicable tube:
 Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm  | 
||||
| No
 restrictions  | 
Large tubes | E32-D36T 5M | Applicable tube:
 Transparent tube (no restrictions on diameter)  | 
||||
| Liquid contact
 (heat-resistant up to 200°C)  | 
--- | --- | E32-D82F1 4M | Liquid-contact type | |||
| Sensing
 method  | 
Heat-resistant
 temperature  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
|||
| Through-
 beam  | 
120°C | E32-T51V 1M | 720 | 400 | 260 | 100 | 
| E32-T51V 1M+E39-F1V | 2,000 * | 2,000 * | 1,360 | 520 | ||
| 200°C | E32-T84SV 1M | 1,760 | 950 | 640 | 260 | |
* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
| Sensing
 method  | 
Application | Operating
 temperature  | 
Model | Sensing distance (mm) | |||
|---|---|---|---|---|---|---|---|
| Giga
 mode  | 
Standard
 mode  | 
High-speed
 mode  | 
Super-high-
 speed mode  | 
||||
| Limited-
 reflective  | 
Glass
 presence detection  | 
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
| Glass
 substrate alignment  | 
E32-A08 2M | 10 to 20 | --- | ||||
| 300°C | E32-A08H2 3M | ||||||
| 70°C | E32-A12 2M | 12 to 30 | --- | ||||
| Glass
 substrate mapping  | 
E32-A09 2M | 15 to 38 | --- | ||||
| 300°C | E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
| Wet processes:
 Cleaning, Resist developing and etching  | 
60°C | E32-L11FP 5M | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)  | 
||||
| Wet process:
 Resist stripping  | 
85°C | E32-L11FS 5M | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)  | 
||||
| Through-
 beam  | 
Wafer mapping | 70°C | E32-A03 2M | 3,220 | 1,780 | 1,200 | 500 | 
| E32-A03-1 2M | |||||||
| E32-A04 2M | 1,280 | 680 | 450 | 200 | |||
| E32-T24SR 2M | 4,000 * | 2,200 | 1,460 | 580 | |||
| E32-T24S 2M | 4,000 * | 2,600 | 1,740 | 700 | |||
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
last update: April 7, 2025